background image

ENGLISH

ENGLISH

MAINTENANCE & CARE

13

15

14

FAUCET FUNCTIONS

12

CAUTION:  Maintenance

DISASSEMBLY

1.  Replacement parts may be available at the store where you purchased your faucet.

2.  When replacement parts are not available, please write or call Pfister Consumer 

Service.

3.  

Always turn off water and relieve pressure before working on your faucet.

NOTE:  Trim Care

Cleaning Instructions:

For all Handles and decorative finishes, use only a soft damp cloth to 

clean and shine.  Use of polish, detergents, abrasive cleaners, organic 

solvents or acid may cause damage.  

Use of other than a soft damp 

cloth will nullify our warranty!

Special Trim:

  

Trim  products  which  contain  Porcelain  or  other  similar  substance  are 

not acceptable for public areas or Commercial use.  Installation of Said 

Trim is at Users Risk!

1–800–PFAUCET (1–800–732–8238)

For Toll-Free Pfaucet information call 

1–800–PFAUCET (1–800–732–8238) 

or visit www.pfisterfaucets.com

•   Installation Support

•   Care and Warranty Information

13  VALVE FUNCTION

By lifting Lever Handle (

13A

) up, the valve will be activated allowing water to flow.  The 

water flow will increase by continuing to lift up Lever Handle (

13A

).  By rotating Lever 

Handle (

13A

) counterclockwise, the water temperature will decreased to full cold.  By 

rotating Lever Handle (

13A

) clockwise, the water temperature will increased to full hot.

Note:

 Flush faucet before turning on valve (

see step 14

).

14  FLUSHING & AERATOR CLEANING

After installation is complete, remove Aerator Housing (

14A

). Turn Valve (

14B

) on 

and allow both hot and cold water to run for at least one minute each. While water is 

running, check for leaks.  To clean the aerator, disassemble Aerator Housing (

14A

) by 

separating the Aerator Shell (

14C

), Basket (

14D

), and Washer (

14E

).  Once parts have 

been cleaned, reassemble by reversing steps.

15  CARTRIDGE REPLACEMENT & HANDLE REMOVAL

Turn off water supplies and relieve pressure before working on your faucet.

Using a 

3

/

32

” Allen wrench, loosen Set Screw (

15A

) and remove Handle (

15B

).  Remove 

Dome Cap (

15C

) and Retainer Nut (

15D

) by unscrewing counterclockwise.  Carefully 

remove Cartridge (

15E

) by pulling it straight up and out.  Inspect and replace as necessary.

Reassemble faucet by reversing steps.

12  SPOUT  FUNCTION

Spout (

12A

) can be rotated around the Faucet Body in any direction.

4

HOT

COLD

ON

15A

13A

14A

13A

14B

14E

14D

14C

15B

15C

15D

15E

12A

Содержание Ashfield LG72 Series

Страница 1: ...esta garantía el comprador original puede 1 llamar al 1 800 Pfaucet 1 800 732 8238 para hablar con un representante de servicio al cliente que lo pueda ayudar o 2 escribir al departamento de servicio al consumidor c o Pfister Inc 19701 DaVinci Lake Forest CA 92610 U S A e incluir una descripción del problema el número del modelo su nombre dirección número de teléfono y fecha aproximada de compra o...

Страница 2: ...cet from the sink and clean the sink surface thoroughly 3 TOOLS RECOMMENDED Plumber s putty Slotted screwdriver Phillips head screwdriver Pliers Adjustable wrench Flashlight Cloth Your installation may require new supply lines and or shut off valves or other additional tools 4 CHECKING THE CONTENTS OF THE BOX Upon opening the box check to ensure that all of the following items are included A Spout...

Страница 3: ...le to push any further Pull down on Connector 9A If the housing and the Inner Collet 9D separate slightly but do not pull off the Inlet Tube 9C connection is secure To remove the quick connect attachment Push up on Connector 9A Holding Inner Collet 9D in place pull downward on Connector 9A until Inlet Tube 9C is free 10 WATER SUPPLY CONNECTIONS Gently separate hot and cold supply tubes 10A approxi...

Страница 4: ... water to flow The water flow will increase by continuing to lift up Lever Handle 13A By rotating Lever Handle 13A counterclockwise the water temperature will decreased to full cold By rotating Lever Handle 13A clockwise the water temperature will increased to full hot Note Flush faucet before turning on valve see step 14 14 FLUSHING AERATOR CLEANING After installation is complete remove Aerator H...

Страница 5: ...ca de cómo instalar este producto Este producto debe instalarse de acuerdo a los códigos de plomería y de construcción locales y estatales 2 CIERRE EL SUMINISTRO DE AGUA Ubique las entradas del suministro de agua y cierre las válvulas de suministro de agua Generalmente se encuentran debajo del fregadero o cerca del medidor de agua Si se trata de un reemplazo de grifo quite el grifo viejo y limpie ...

Страница 6: ... hacia abajo el conectador 9A Si la caja y la boquilla interior 9D se separan ligeramente pero no se desprenden del tubo de recibo 9C la conexión está firme Para quitar el accesorio de el conectador empuje hacia arriba el conectador 9A Manteniendo la boquilla interior 9D en posición empuje hacia abajo el conectador 9A hasta que el tubo de recibo 9C se desprenda 10 CONEXIONES DE SUMINISTRO DE AGUA ...

Страница 7: ... manija de palanca 13A la válvula se activará y permitirá el flujo de agua El flujo de agua aumentará al continuar levantando la manija de palanca 13A Al girar la manija de palanca 13A en sentido contrahorario la temperatura del agua disminuirá hasta completamente fría Al girar la manija de palanca 13A en sentido horario la temperatura del agua aumentará hasta completamente caliente Nota Debe purg...

Страница 8: ...et nettoyer soigneusement la surface de ce dernier 3 OUTILLAGE RECOMMANDÉ Mastic de plombier Tournevis plat Tournevis cruciforme Pince Clé à molette Lampe de poche Chiffon L installation peut exiger des tuyaux d arrivée et ou des vannes d arrêt neufs ou d autres outils 4 VÉRIFICATION DU CONTENU DE LA BOÎTE Lors de l ouverture de la boîte vérifier son contenu pour s assurer que toutes les pièces su...

Страница 9: ...t le récepteur intérieur 9D se séparent légèrement sans se désaccoupler le raccord du tube récepteur 9C est bien assujetti Pour débrancher le raccord rapide pousser le connecteur 9A vers le haut Tout en maintenant le récepteur intérieur 9D en place tirer le connecteur 9A de raccord rapide vers le bas jusqu à ce que le tube récepteur 9C soit libéré 10 RACCORDEMENTS DES ARRIVÉES D EAU Écarter avec p...

Страница 10: ... permettre à l eau de couler Le débit augmente au fur et à mesure que l on relève la manette 13A Lorsqu on tourne la manette 13A dans le sens antihoraire la température de l eau baisse jusqu à ce que celle ci soit tout à fait froide Lorsqu on tourne la manette 13A dans le sens horaire la température de l eau augmente jusqu à ce que celle ci soit très chaude Note Il doit purger le robinet avant d o...

Страница 11: ...FRANÇAIS FRANÇAIS 11 ...

Страница 12: ...ter Peltre Rústico Étain Rustique J PVD Brushed Nickel PVD Niquel Cepillado PVD Nickel Brosse U Rustic Bronze Bronce Rústico Bronze Rustique Y Tuscan Bronze Bronce Toscano Bronze Le Toscan Z Oil Rubbed Bronze Bronce Frotado Con Aceite Bronze Huilé 941 508 920 064 971 130 940 141 971 052 941 777 950 121 931 041 962 075 974 074 962 074 974 043C Gray Gris Gris 974 043B Black Negra Noire 949 038C Gray...

Отзывы: