Fig. 15:
Temperature monitoring
1
Locking screw of the measurement connection
3
Installation dimension X
2
Fore-vacuum flange
4
Thermometer
Required tools
● Open-end wrench, WAF 17
Faulty temperature measurement
The measurement is faulty if the installation dimension is not observed. No maxi-
mum values will be measured.
Procedure
1. Unscrew the locking screw of the measurement connection hole at the discharge channel.
2. Mount the clamping screw fitting for the thermometer.
3. Mount the filling pipe in the clamping screw fitting.
4. Set the installation dimension
X = 241,3 mm
and tighten the clamping screw fitting tight.
5.10.3 Installing a protective strainer
Installing a protective strainer
1. Install an appropriate protective strainer at the vacuum connection in case there is a risk that solid
matter is sucked along.
2. Clean the protective strainer at regular intervals.
Installation