![Pfeiffer Vacuum OKTA 2000 ATEX Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/pfeiffer-vacuum/okta-2000-atex/okta-2000-atex_operating-instructions-manual_1535128014.webp)
CAUTION
Danger of burns on hot surfaces
Depending on the operating and ambient conditions, the surface temperature of the vacuum pump
can increase to above 70 °C.
► Provide suitable touch protection.
Risks during maintenance, decommissioning and malfunctions
DANGER
Risk of explosion when carrying out installation and maintenance work in potentially explo-
sive areas
There is a risk of explosion if unsuitable tools are used in potentially explosive areas. Ignition can
cause very serious injuries.
► Transport, installation and maintenance work may not be performed in potentially explosive at-
mospheres.
► Always shut down the vacuum pump before commencing any work.
DANGER
Risk of explosion from electrostatic charging during transport
There is a risk of fatalities when transporting packaging material (foil) and plastic containers in poten-
tially explosive areas. Ignition can cause very serious injuries, and even fatalities.
► Only unpack the vacuum pump outside of potentially explosive areas.
WARNING
Health hazard through poisoning from toxic contaminated components or devices
Toxic process media result in contamination of devices or parts of them. During maintenance work,
there is a risk to health from contact with these poisonous substances. Illegal disposal of toxic sub-
stances causes environmental damage.
► Take suitable safety precautions and prevent health hazards or environmental pollution by toxic
process media.
► Decontaminate affected parts before carrying out maintenance work.
► Wear protective equipment.
WARNING
Danger to life from electric shock in the event of a fault
In the event of a fault, devices connected to the mains may be live. There is a danger to life from
electric shock when making contact with live components.
► Always keep the mains connection freely accessible so you can disconnect it at any time.
WARNING
Danger of injury due to bearing damage
If the valid temperature range of the permissible lubricants is exceeded, insufficient lubrication can
lead to bearing damage. There is a risk of explosion due to causing an ignition hazard, and a risk of
serious injuries.
► Exclusively utilize the permissible lubricants for the intended temperature range.
► When filling, refilling, or changing the lubricant, always utilize the lubricant type specified on the
rating plate.
WARNING
Risk of crushing from rotating parts
Fingers and hands may be caught by rotating pistons within the connection flange. This results in se-
vere injuries.
► Keep limbs out of the reach of the roots pump.
Safety