![Pfannenberg PY L-S Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/pfannenberg/py-l-s/py-l-s_operating-instructions-manual_1534774013.webp)
Operating instructions PY L-S
03/2021
Page 6 / 7
086200015b
en
7.2 Setting the operating modes - versions with multicolor LED
Circuit board in the lens:
S1
Selection of
operating mode
Light intensity control
Flashing light:
10 – 100%
Blinking- / Continuous light:
45 – 100%
7.2.1
without external control
S1
Operating mode
1
2
3
OFF OFF OFF
Flashing light 1 Hz
*
OFF OFF ON
Flashing light 0.75 Hz
OFF ON OFF
Continuous light
OFF ON ON
Blinking light 1 Hz
ON OFF OFF
Flashing light 2 Hz
ON OFF ON
Blinking light 2 Hz
ON ON OFF
Flashing light 0.1 Hz
ON ON ON
Flashing light 0.5 Hz
OFF OFF ON
Double Flash mode (DFM3) see
*
Factory setting
S1
Color assignment
4
5
6
OFF
OFF OFF
Red
*
OFF ON
Blue
ON OFF
Green
ON ON
Yellow
7.2.2
with external control
Setting on the circuit board in lower part:
S1
Operating mode
1
2
3
4
C1/ C2
not activated
OFF OFF OFF
ON
Standby
Blinking light
1 Hz
Continuous light
Continuous light
OFF OFF ON
Standby
Continuous light
Continuous light
Continuous light
OFF ON OFF
Standby
Blinking light
1 Hz
Continuous light
Blinking light
1 Hz
OFF ON ON
Standby
Flashing light 1 Hz
Continuous light
Continuous light
ON OFF OFF
Standby
Flashing light 1 Hz
Continuous light
Blinking light
1 Hz
ON OFF ON
Standby
Flashing light 1 Hz
Continuous light
Flashing light 1 Hz
ON ON OFF
Standby
Blinking light
1 Hz
Blinking light
1 Hz
Blinking light
1 Hz
ON ON ON
Standby
Continuous light
Continuous light
Blinking light
1 Hz
Standby
DFM1
DFM2
DFM3
OFF OFF ON