55
104 73 15-26
No operation of Foot controller
Check - using Service program
1. Go to the service program of the machine.
2. In Menu 2 choose the No 4 Foot control sensor.
3. Check if the connector N12 is properly connected to the main board.
4. Check if the connector from the socket is properly connected to the main board.
5. Check if the foot control cable is properly connected to the socket and that there is no big play in-
between the foot control cable and socket .
If there is a big play.
- Check with another foot control.
- Replace the socket.
If there is still no function.
- Replace the main board.
No function of LED lamp
Check if connector N3 is properly connected to the main board and that there is no damage to the lamp
socket.
If there is still no function.
-Replace the connection board for the LED lamp - located on top of the armshaft.
-Check if LCD cabels are properly connected to the connection board for the LCD lamp.
If there is still no function.
-Replace the lamp socket
Fault fi nding Ambition 1.0 - 1.5