Adjustment
11 - 7
62-0211
11
.04.06
Positioning the feed dog
Requirement
When the maximum stitch length is set, the feed dog
4
should move laterally and
lengthwise in the centre of the needle plate cut-out.
Fig. 11 - 06
●
Align device
1
(screws
2
and
3
) in accordance with the
requirement
.
1
3
2
62-068
4
=
=