Adjustment
13 - 35
13
.11.02
Selecting the user level
●
Switch on the machine.
●
Call up the input mode.
●
Call up parameter "798".
A 100
100
●
By selecting the appropriate value for parameter
798
, the user level is determined and
shown in the display in front of the current parameter.
"0"
=
Operator level A
"1"
=
Mechanic level B
"11"
=
Service level C
●
End the parameter input. The altered values are stored and the controller switches to the
sewing mode.
A 798
0