Adjustment
13 - 8
13
.05.06
Feeding motion of the needle feed
Requirement
With the needle bar positioned
0.6 mm past b.d.c.
the needle should not move, when
shaft
3
is turned backwards and forwards.
Fig. 13 - 07
●
Position the needle bar at 0.6 mm past b.d.c.
●
Adjust eccentric
1
(screws
2
) according to the
requirement.