Adjustment
13 - 47
13
.11.03
List of parameters
Group
P
arameter
Description
User level
S
et
ting range
S
et value
0
10
Bobbin thread monitor-current level
C
8 - 16
12
11
Bobbin thread monitor-stitch counter (starting
value)
C
0 - 255
32
1
100
Control panel contrast [%]
A
80 - 110
90
101
Control panel key response signal
0=tone off
2=tone on
A
0 - 3
2
102
Start backtacks forwards
C
0 - 9
3
103
Start backtacks in reverse
C
0 - 9
3
105
Start backtacks speed
B
100 - 1500
900
106
Start backtacks speed
ON = pedal-controlled
OFF = set with param. "105"
C
ON - OFF
OFF
107
Pedal-controlled speed start backtacks
ON = limited with parameter "105"
OFF = limited with parameter "607"
C
ON - OFF
OFF
108
End backtacks in reverse
C
0 - 9
3
109
End backtacks forwards
C
0 - 9
3
110
End backtacks speed
B
100 - 1500
1000
111
No. of stitches from bright light barrier to
seam end in manual sewing
A
1 - 255
6
113
Start with light barrier
ON = only when light barrier is dark
OFF = also when light barrier is bright
B
ON - OFF
ON
114
After light barrier or stitch counting
ON = stop
OFF = autom. end backtacks and seam end
C
ON - OFF
OFF
116
Soft start stitches (soft start)
A
0 - 10
1
117
Speed for soft start stitches
B
180 - 1200
600
148
Start backtacks
ON = double / OFF = single
A
ON - OFF
ON
149
End backtacks
ON = double / OFF = single
A
ON - OFF
ON
Содержание 2438 plusline
Страница 111: ...Wearing parts 14 2 99 137 151 45 91 171 049 05 91 171 042 05...
Страница 113: ...15 2 Circuit diagram View Version 23 01 03...
Страница 114: ...15 3 91 191 445 95 Part 1 Version 29 01 02 Circuit diagram...
Страница 115: ...15 4 Circuit diagram Version 29 01 02 91 191 445 95 Part 2...
Страница 116: ...15 5 91 191 445 95 Part 3 Version 29 01 02 Circuit diagram...
Страница 117: ...15 6 Circuit diagram Version 29 01 02 91 191 445 95 Part 4...