34
Adjustment
Group
Gruppe
Parameter
Parameter
Description
Bedeutung
Setting
range
Set value
000
006
Reversing after thread trimming
Reverse position [°]
With this parameter it is possible to
switch the automatic reversing func-
tion after thread trimming on or off. If
the reversing function is switched on,
the reverse position can be set by tur-
ning the balance wheel. The access
code is necessary for this adjustment.
ON - OFF
0 - 14
ON
11
007
Starting point = scale reference
point
With this parameter it is possible to
choose whether the scale reference
point is the starting point (ON) or the
zero point (OFF).
ON - OFF
OFF
008
Speed for the "winding" function
This parameter is used to fi x the
speed for the winding operation.
200 - 2700
1500
009
Via zero point to starting point after
end of sequence
With this parameter it is possible to
choose that, after the end of the
sequence, the X-, Y-drive moves to the
seam starting point via the reference
initiators.
ON - OFF
OFF
010
Via zero point to starting point after
number of program cycles Number
of program cycles
With this parameter it is possible to
choose that, after a certain number of
program cycles, the X-, Y-drive moves
to the seam starting point via the refe-
rence initiators.
ON - OFF
1 - 100
OFF
011
Pedal mode
Switchover between level mode (
0)
and fl ip fl op mode (
1).
0 - 1
0
012
Needle or balance wheel position
in degrees
0 - 360
11