33
Adjustment
1
.31
List of parameters
The parameter setting values my only be altered by appropriately trained staff!
Group
Gruppe
Parameter
Parameter
Description
Bedeutung
Setting
range
Set value
000
001
Maximum speed
This parameter is used to fi x the max.
sewing speed (upper limit).
500 - 2700
2700
002
Sewing speed for start stitches
With this parameter the speeds for
the
5
start stitches are fi xed.
Speed (spm) for start stitch no.
1
Speed (spm) for start stitch no.
2
Speed (spm) for start stitch no.
3
Speed (spm) for start stitch no.
4
Speed (spm) for start stitch no.
5
500 - 2700
500 - 2700
500 - 2700
500 - 2700
500 - 2700
500
900
2700
2700
2700
003
Locking/releasing seam patterns
This parameter is used to release (ON)
or lock (OFF) the individual seam
patterns (
0
to
99)
to be carried out in
the sewing mode.
ON - OFF
ON
004
Switch bobbin thread counter on/off
Standard value (pieces per bobbin)
In the sewing mode, the bobbin thread
counter counts the pieces sewn back-
wards from the standard value. If the
bobbin thread counter is
switched on, in the sewing mode a
signal is given when the value
0
is re-
ached.
ON - OFF
1 - 9999
OFF
11
005
Sequence combination
This parameter is used to combine se-
veral sequences with each other.
0 = no combination
1 = C1 with C2
2 = C2 with C3
3 = C1 with C3
4 = C1 with C2 and C3
0
- 4
0