Wiring & Programming
in
Parking and access control equipment manufactured in the UK
Automatic Sliding Gates
1. Enter menu by pressing “stop” and “up” together
3. Press “stop” key to view parameter currently shown on
display
2. Use “up” and “down” arrows to scroll through parameters
4. LED dot flashes when changes are un-saved - press and
hold stop to save changes you have made
1.
2.
4.
3.
60 5
10
15
20
25
30
35
40
45
50
55
10 mins
STOP
P.999
.0.99
LED Dot
Normal State = Static
Changed State = Flashing
LED Letters
or numbers
Reminder of how to enter/exit and navigate menus:
STOP
STOP
Outputs
Parameter
Unit Range
Function
Description/Value of Parameter
P.7x0
0 ..... 27
Switching Condition
of output relay
With this parameter the functionality for parameter x is set.
12:
Traffic light function
This setting involves additional settings under Parameter P.7x6 to P.7xd.
14:
Position forwarding
This setting involves additional settings under P.7x5.
15:
Output warning message from maintenance counter
16:
Airlock OPEN, forwards OPEN command to second airlock door
17:
Test of draw in safety device.
Relay is active in Endposition Close and is used e.g. to switch of the photo eye of the draw in
safety in order to test it.
If this Function is used, you must use the N.O.(normally open) contact of the relay, because
the relay is switched on if the Test-Mode doesen`t work.
25:
Test at the End-Position Door Open
Relay works at the End- Position Door Open
If this Function is used, you must use the N.O.(normally open) contact of the relay, because
the relay is switched on if the Test-Mode doesen`t work.
27:
If the case temperature falls under the value adjusted with Parameter P.428
Notes Area...
P.7x1
0 ..... 1000,0
{Seconds}
Switching behaviour
of relay
This parameter is used to set the switching behavior of the relay after activation.
0:
Relay flashes at 1Hz
1-999:
Turn-on duration of the relay in seconds
1000:
Relay continuously turned on
P.7x2
0 ..... 999,9
{Seconds}
Turn-on delay
The relay is turned on after a time delay specified in this parameter.
P.7x3
0 ..... 999,9
{Seconds}
Turn-off delay
The relay is turned off after a time delay specified in this parameter.
P.7x4
0 ..... 1
Contact type
0:
Normally Open
1:
Normally Closed