13. Safety Inspection
All inspections and repairs must be recorded in the maintenance diagram. This does not only apply to your own
inspections but also for inspections which are carried out by your authorised pewag distributor. When the clamp is
handed in for maintenance and inspection, you must always provide the maintenance diagram.
Defective Lifting Clamps
When a form of wear or damage is indicated, you must take the following measures:
• Take the lifting clamp out of service (note the date of failure of the lifting clamp)
• Try to identify the cause of the failure (complete list is available in Chapter 10). Such damages are not covered by
the warranty! To guarantee your own safety and that of your colleagues you are obliged to follow this procedure
• Return your lifting clamp (with the maintenance history) to an authorised mechanical repair centre
• If the lifting clamp has been revised/repaired, you can safely use your clamp again. Please note this date in your
maintenance chart
14. Inspection Schedule
Months
4
8
12
16
20
24
28
32
36
40
44
48
52
56
60
Years
1
2
3
4
5
Safety inspections by
your own inspector
Maintenance by an
official pewag distributor
Revision by an official
pewag distributor