background image

 

10 

Installation and Operating Instructions for Newbourne 40i Inset Inset Ecodesign Multi Fuel Stove 

Ref: Pevex1030/AH/ver1: 1 April 2019 

6.  Leave instructions for customer 
7.  Check that after initial firing the door seals are not stuck to the body of the stove 

WARRANTY 

The Newbourne 40i Inset stove range is automatically covered by a 12-month warranty for safety, performance 
and construction.  This can be extended by a further  4-year conditional warranty providing that the stove has 
been  installed  by  a  Hetas  approved  engineer  or  suitably  signed  off  by  local  building  control  covering  the 
installation of the stove and, by registering your product within 1 month of the purchase of the stove.   
 
Under the Terms and Conditions of the extended warranty, the installation of the stove will need to both comply 
with the current building regulations and be installed by a qualified Hetas engineer. Furthermore, the stove must 
be  serviced  and  maintained  annually  by  a  suitably  qualified  Hetas  or  chimney  engineer  and  the  certificate  of 
installation and all records/receipts and annual servicing records  will need to be  provided in the event of any 
claim.   
 
Please note, as is normal practice in the industry, bricks, baffles, glass, grate, log retaining fence, ashpan and 
rope seals are considered wearing parts requiring replacement during routine maintenance and as such are not 
covered under any warranty conditions.   
 
Spare parts can be ordered through the stockist who supplied the stove or directly through ourselves.   
 
In the event of any warranty claim then in the first instance a claim must be made with the stockist or stove dealer 
who  supplied  the  stove  and  must  follow  our  Terms  and  Conditions  as  set  out  below.    It  is  entirely  at  Pevex 
decision whether to repair or replace any part that it considers are defective.  Any repaired or replaced parts are 
covered only for the remaining warranty period of the stove unit. 

 

TERMS AND CONDITIONS 

Your Newbourne 40i Inset stove is guaranteed against any defects providing: 

 

1.  The stove was installed according to our instructions and installation was carried out by a qualified Hetas 

or  an  appropriate  Building  Control  Certificate  of  Completion  was  issued  which  must  accompany  any 
claim 

2.  No damage has occurred during the installation 
3.  The  chimney  has  either  been  inspected  and  repaired  as  necessary  or  replaced  with  a  suitable  flue 

system and any high draught issues have been remedied 

4.  The serial number of the stove must accompany the claim 
5.  The stove must be kept in a continuous serviceable condition with no corrosion evident or allowed to 

have taken place.  If older than 12 months then proof of an annual service record must be provided. 

6.  There has been no modifications made to the construction or internals components or incorrect service 

parts installed 

7.  The stove has not been over-fired through: 

a.  Overfilling the firebox with fuel and/or burning it continuously with fully open air sliders 
b.  Burning  incorrect  or  prohibited  fuels  as  mentioned  on  pages  4  &  5  eg.,  house  coal,  fuels 

containing  high  levels  of  petroleum  coke,  sulphur  or  contaminated  wood  (paint,  varnish, 
creosotes etc) 

8.  Excessive ash when burning wood or solid fuel has been removed 
9.  The stove has not been allowed to slumber continuously overnight 
10.  The stove is not used in a damp environment 
11.  The stove has not been used in a commercial environment (rental property, hotel, public barm etc) where 

there  is  opportunity  for  the  members  of  the  public  who  are  not  familiar  to the  operation  to  misuse  or 
abuse the safe operation of it. 

LIMITATION OF WARRANTY 

The warranty is not transferrable and will only stay with the original retail purchaser.  Copy of the original sales 
receipt will need to be seen as proof of purchase. It does not cover such things as unauthorised modifications 
or repairs, misuse or abuse, accidental damage, illegal installations and if the stove has not been serviced every 
12 months. 
 
Pevex  will  not  under  any  circumstances  cover  any  incidental  or  consequential  loss  which  includes  any 
commercial  loss,  damage  to  any  furnishings,  damage  to  non-related  products,  removal/reinstallation  costs, 
transports delay or additional transport costs or any injury to persons or property.    
 
The Pevex warranty does not affect your statutory rights. 

 

Содержание Newbourne 40i Inset Ecodesign

Страница 1: ...WOOD AND MULTI FUEL INSET STOVE CE and EN13229 Approved SUITABLE FOR INSTALLATION INTO A 16 X 22 HIGH FIREPLACE OPENING Pevex Enterprises Ltd Unit MP7 Kirrawah Business Park Waldringfield Ipswich IP12 4PR Tel 01473 736399 Fax 01473 736406 ...

Страница 2: ...ment and verification of constancy of construction product performance as set out in annex V System 3 Strojirensky Zkusebni Ustav S P Notified No NB1015 6 Notified body relevant to the assessment and verification of performance Not tested NPD pass pass A1 Pass 175 EN13229 2002 A2 2005 0 07 3 Intended use or uses of the construction products in according to the technical specification Pevex Enterpr...

Страница 3: ...toves can be traced back many centuries however it is a forgotten or maybe never fully discovered activity in the United Kingdom we have much to learn from our European and Scandinavian neighbours whose colder winters have instinctively led them into a natural wood burning culture Wood for fuel is probably one of the most environmentally friendly energy sources it is carbon neutral trees used for ...

Страница 4: ...early not only uneconomical to fire with wet fuel but also as mentioned above increases the risk of producing soot smoke and other environmentally damaging by products When wood is used as a fuel it is important that it is dry i e wood with moisture content less than 20 Ideally firewood needs seasoning for at least 2 summers logs should be stacked in a well ventilated situation and logs over 100mm...

Страница 5: ...s LIGHTING AND COMBUSTION The primary air is drawn into the stove through the air slider located on the lower part of the door slide the knob to the right to allow air to enter and slide it in to the left to shut off the air supply Allowing 20 of primary air to enter is a recommended position during normal operation of the stove after the fire has established in the firebox allowing a preset bleed...

Страница 6: ...evening by turning off the air supply is not to be recommended especially when burning solid fuels Not only is this harmful to the environment due to the incomplete combustion of the fuel but there is a potential to create longer term problems to the stove internals which includes the glass door panel and flue components Incomplete combustion of the fuel will lead to gas build up in the fire chamb...

Страница 7: ...ffect the performance of a chimney In cases where the wood burns too quickly this may be due to excessive chimney draught You should also check to make sure that the door seal is intact If the stove produces too little heat this may be due to the fact that you are firing with wet wood A large proportion of the heat output will be used to dry the wood resulting in both uneconomical heating and an i...

Страница 8: ...ve Having decided on the ideal appliance then the installation should be fully assessed The chimney requirements should be carefully assessed Hearth requirements should be carefully specified remember the building regulations lay out the minimum requirements The chances of damaging a floor or carpet will be much reduced if the depth of a hearth is extended beyond the minimum Any combustible materi...

Страница 9: ...ot more than a 1 metre length of plain un insulated pipe is used before connection to a chimney system and that no combustible materials are within 500mm of the flue pipe Baffle plate removal The Newbourne 40i Inset Ecodesign stove is fitted with a twin baffle system to improve efficiency and lower CO emissions with the lower one made from vermiculite and the upper one made from steel Removal of t...

Страница 10: ...installed according to Building Regulations Approved Document J and its diameter must be not less than the diameter of the outlet of the appliance The fluepipe must be adequately sealed to both the stove and the chimney to avoid any leakage We recommend also that no more than 1metre of plain un insulated flue pipe be used to connect to the chimney ALL CHIMNEYS SHOULD BE SWEPT AND INSPECTED BEFORE ...

Страница 11: ... according to our instructions and installation was carried out by a qualified Hetas or an appropriate Building Control Certificate of Completion was issued which must accompany any claim 2 No damage has occurred during the installation 3 The chimney has either been inspected and repaired as necessary or replaced with a suitable flue system and any high draught issues have been remedied 4 The seri...

Страница 12: ...use in smoke control areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid ...

Страница 13: ...l 2019 APPENDIX B TECHNICAL SPECIFICATIONS NEWBOURNE 40i INSET ECODESIGN STOVE Newbourne 40i Inset Ecodesign Width x max depth x height 545 x 371 x 606 Weight kg 70 Log length mm 260 Flue dia top only mm 128 or 150 Nominal Output kW 4 9 Efficiency Net Wood 77 Efficiency Net Ancit 80 5 Energy Efficiency Label A CO 13 O2 Wood 0 07 ...

Страница 14: ... Inset with flue pipe connection Fix firmly to chair brick with fixing bolts not supplied Remove side and rear bricks in stove to access predrilled holes Chair brick Skamolex Blue calcium silicate board cut and shaped to form heat insulator or rockwool insulation Weak mix vermiculite infill or rockwool Fix firmly to chair brick with fixing bolts not supplied Remove side and rear bricks in stove to...

Страница 15: ...World of Stoves A World of Choice Pevex Enterprises Ltd Unit MP7 Kirrawah Business Park Waldringfield Nr Woodbridge IP12 4PR Tel 01473 736399 Fax 01473 736406 sales pevexstoves co uk www pevexstoves co uk ...

Отзывы: