SERVICE OPERATIONS
32
Reproduction or translation, even partial, is forbidden without the written consent of Peugeot Motocycles
- Install the screw and its seal.
- Fill the circuit with 0.9 L of coolant.
- Loosen the bleeder screw (2) to remove air
contained in the engine.
- Close the bleeder screw.
- Check and top up the coolant level in the
radiator.
- Start the engine and accelerate in order to
warm it up.
- Allow the engine to cool down.
- Stop the engine once it reaches its operating
temperature.
- Check and top up the coolant level in the
radiator.
- Check the coolant level in the header tank.
- The level of coolant should be between the
minimum (A) and maximum (B) markers
without exceeding the latter.
2
MIN
MAX
B
A