 Test for Collar Fit

This test is an added feature to verify fit but is not required for the system to function. After the ReadyTest

®

, the 

Receiver Collar will go into PerfectFit

 test mode. This mode begins with a flashing yellow light. To use this feature, 

you must place the Receiver Collar on your dog within 90 seconds of removing it from the Collar Charger. The 

Receiver Collar will emit a chime tone as the Contact Points touch your dog’s skin. You will know you have the proper 

fit when the collar chimes and flashes green 5 consecutive times. After 90 seconds, the Receiver Collar moves into 

normal operation mode.
The Receiver Collar will still function normally if you are unable to place the Receiver Collar on your dog within 90 

seconds of removing it from the Collar Charger. If you wish to use the PerfectFit

 test after 90 seconds have passed, 

place the Receiver Collar back on the charger for 5 seconds. Remove the collar and allow it to complete the ReadyTest

®

 

before placing it on your dog.

See Step 11 for proper fit before you place collar on your pet.

Receiver Collar Status Indicators

The Receiver Collar Status Indicator Light along with the Receiver Collar Alarm Tone are used to determine the 

operational mode, the battery status, and the correction type. Refer to the Receiver Collar Status Indicator Table 

below to understand the status lights and tones for the Receiver Collar. During normal operation, the Receiver 

Collar Indicator Light will flash every 3 seconds to indicate the battery status as shown in the table below. 

Receiver Collar Status Indicator Table

Status Light

Alarm Tone

Condition

While on Charger

Solid Red

No Tone

Charge in progress

Solid Green

No Tone

Charge complete

No Light

Charge failure, contact Customer Care Center

After Removing From Charger ReadyTest

®

 & PerfectFit

 Test

Off (1 second) followed by  

Red (3 seconds)

No Tone

Unit is performing ReadyTest

®

Continuous Green/Yellow/Red (5 seconds)

No Tone

Battery Charge Indicator

Continuous Red

20 sec.

ReadyTest

®

 failure; unit is not operational, contact 

Customer Care Center

Flashing Yellow (every 1 second)

No Tone

Unit is in PerfectFit

 mode for 90 sec. after turning on

Flashing Green (every 1 second)

Chime; 5 consecutive chimes for 

confirmed fit

PerfectFit

 mode indicates collar is making true contact with 

dog's skin

Fast Pulsating Green

Warning Tone

Warning tone 

Fast Pulsating Red

Duration of the Stimulation

Stimulation being delivered (up to 10 sec.)

Continuous Green (10 seconds)

No Tone

Over Correction Protection; collar locked for 10 sec.

Slow Blinking Green (every 3 seconds)

No Tone

Collar battery charge 100% - 60%

Slow Blinking Yellow (every 3 seconds)

No Tone

Collar battery charge 60% - 20%

Slow Blinking Red (every 3 seconds)

No Tone

Collar battery charge 20% or less; charge immediately

Anti–Linger Prevention

The Anti-Linger Prevention feature keeps your dog from staying in the Warning Zone for long periods of time and 

draining the Receiver Collar battery. Your dog will hear a two second warning tone when he reaches the Warning Zone. 

If your dog does not return to the Pet Area after two seconds, he will receive a continuous Static Correction until he 

returns to the Pet Area.

Run Through Prevention

This system includes a unique “run-through” prevention so that your dog cannot escape the Pet Area without 

receiving an increased level of Static Correction. The Receiver Collar automatically increases the Static Correction 

when your dog continues more than 

1

3

 of the way through the pet fencing Field Width. For example, if the signal 

is detected 12 feet from the wire and your dog enters the Static Correction Zone, this feature is activated when 

he is approximately 8 feet from the Boundary Wire. Your dog will then receive a Static Correction that is at an 

increased level corresponding to the Static Correction level setting on the Fence Transmitter. 

Over Correction Protection

In the unlikely event that your pet “freezes” in the Static Correction Zone, this feature limits the Static Correction 

duration to 10 seconds. While the system locks out further Static Correction, the green light will remain on for 10 

seconds before resuming the correction with tone for another 10 seconds. This pattern will repeat for a maximum of 

three cycles, a duration of 60 seconds, or until the pet leaves the Static Correction Zone.

Содержание ultrasmart in-ground fence PIG00-13619

Страница 1: ...ultrasmart in ground fence operating and training guide Model Number PIG00 13619 Please read this entire guide before beginning...

Страница 2: ...hers If you are not sure that this product is right for your dog please talk to your veterinarian or a certified trainer Underground cables can carry high voltage Have all underground cables marked be...

Страница 3: ...is may lead to a rash or infection The Receiver Collar should not be on your dog when the system is tested Your pet may receive an unintended correction The Boundary Width of the system must be tested...

Страница 4: ...5 How the System Works 6 Key Definitions 6 Operating Guide 7 Install the Fence Transmitter 7 Charge the Receiver Collar 7 Lay Out the System 8 Sample Layouts 8 Position the Boundary Wire 9 Prepare the...

Страница 5: ...E REA D THIS ENT IRE GUI DE BEF ORE BEG INN ING Other Items You May Need Additional wire and flags Part PRFA 500 Tape measure Small Phillips screwdriver Drill Shovel or lawn edger Pliers Wire strippin...

Страница 6: ...in the Static Correction Zone Surge Protector Installed with the Fence Transmitter to protect it from lightning strikes and power surges Receiver Indicator Light Reflects the battery status and corre...

Страница 7: ...he Receiver Collar The Receiver Collar Charger is designed to plug into a standard AC wall outlet and act as a charging stand for the Receiver Collar Choose a location close to a door that you and you...

Страница 8: ...the Warning and Static Correction Zones to approximately 16 24 feet 8 12 feet on each side of the wire The Receiver Collar can be activated inside the house if the Boundary Wire runs along the outside...

Страница 9: ...g fence It reduces the amount of wire which will need to be buried Run the wire from the Fence Transmitter to A A to B B to C C to D D to E E to F make a U turn and follow your path all the way back t...

Страница 10: ...Make sure the copper Boundary Wire is not TWISTED WIRES BOUNDARY WIRE WATERPROOF SPLICE CORRECT INCORRECT 4C corroded If the Boundary Wire is corroded cut it back to expose clean copper wire Insert t...

Страница 11: ...A Setting will alert after 60 days and the B setting will alert after 30 days To set the reminder turn the switch to the OFF position then move to either the A or B setting After the 30 or 60 days has...

Страница 12: ...ong outlet converter Doing so will make the Surge Protector ineffective against surges or spikes 1 Turn the power OFF to the outlet that the Surge Protector and Fence Transmitter will be plugged into...

Страница 13: ...icating a properly installed boundary loop If this does not happen refer to the Transmitter Status Indications label underneath the transmitter lid 6C or see the Troubleshooting section in this guide...

Страница 14: ...l contact Customer Care Center Flashing Yellow every 1 second No Tone Unit is in PerfectFit mode for 90 sec after turning on Flashing Green every 1 second Chime 5 consecutive chimes for confirmed fit...

Страница 15: ...ning tone you have identified the Field Width distance Static Correction Zone Two seconds after the warning tone the test light will begin to flash This flashing light can aid you in identifying the F...

Страница 16: ...y Wire on top of the fence and return it on the bottom of the fence to get the five foot separation needed Chain Link Fence 9A Weave Boundary Wire through the links or use plastic quick ties Wooden Sp...

Страница 17: ...mmonly known as bed sores Avoid leaving the collar on the dog for more than 12 hours per day When possible reposition the collar on the pet s neck every 1 to 2 hours Check the fit to prevent excessive...

Страница 18: ...ar 5 The Receiver Collar should fit snugly yet loose enough to allow one finger to fit between a Contact Point and your pet s neck 11F Allow your pet to wear the collar for several minutes then rechec...

Страница 19: ...n on a positive note with lots of praise and play Remove the Receiver Collar after each training session Be sure to contain your pet by another means during the training period e g pen tie out leash e...

Страница 20: ...eness Introduction to Static Correction Perform three sessions per day each lasting 10 15 minutes Goal To train your pet to stay in the Pet Area and respect the boundary Setup Set the Static Correctio...

Страница 21: ...pet anytime he comes back into the Pet Area with or without help 6 Repeat this process with other distractions Use other family members during this process 7 If your pet does not respond to the Stati...

Страница 22: ...home and can teach your pet to stay off of furniture away from trash or out of certain rooms The small battery operated Indoor Barrier fits discreetly inside your home and protects a circular area up...

Страница 23: ...ol knob clockwise to increase the distance from the Boundary Wire that the Receiver Collar activates You can also adjust the Field Size Switch to another setting If using a Double Loop make sure Bound...

Страница 24: ...and Receiver collar setting before beginning the System Test Follow the steps below to perform the system test 1 Remove the Receiver Collar from your dog and make sure it is fully charged 2 Turn the...

Страница 25: ...imple test to determine the cause of a Boundary Wire Broken or Disconnected alarm indication You will need a short 15 foot piece of Boundary Wire with 3 8 inch of insulation stripped from both ends To...

Страница 26: ...Wire to either side of your Boundary Wire where you cut it in half 7 Plug in the Fence Transmitter and check the Status Indicator Light If the Status Indicator Light glows solid green you can assume...

Страница 27: ...hich the receiver is connected Contact the Customer Care Center This device complies with Industry Canada Rules This device complies with part 15 of the FCC Rules Operation is subject to the following...

Страница 28: ...677 www petsafe net 400 1427 1 Covered by US Patents 6 184 790 6 327 999 6 459 378 6 807 720 7 046 152 7 068 174 7 117 822 7 204 204 7 278 376 7 345 588 7 394 390 7 404 379 7 426 906 7 495 570 7 574 9...

Отзывы: