Petersen Products 128 Series
Removing the Line Stop Plug
29
Removing the Line Stop Plug
Remove the Inflation and Pressure Monitor Hoses from the Inflation Ram.
Open valve on Inflation Ram Pulley Assembly to allow air to vent when removing the Line Stop Plug from the pipe.
Relax the Rachet Assembly. Disconnect the Rachet Assembly from the Eyebolts on the Packing Seal.
Loosen the set screws to remove the top of the Inflation Ram.
NOTE
The stop collar must be on the Inflation Ram at all times.
Attach the Pull block to the Inflation Ram. Tighten the Set Screws to secure the Pull Block to the Inflation Ram.
Attach the Ram sections to the Ram Removal Plate. Tighten the Set Screws to secure the Ram Sections in place.
Attach the Pully Assembly to the Ram Sections. Tighten the Set Screws to secure the Pully Assembly in place.
NOTE
The Ram Removal Plate is rated for 5 feet of Ram in a vertical position.
Loop the chain around the Pully Assembly and connect the Ratchet Puller to the Pull Block and Ram Removal Plate.
After one section of the Inflation Ram is retracted, attach a Stop Collar at the lower Ram section to prevent the Ram from
falling back down into the pipe.
Remove the Inflation Ram one section at a time. Move the Pull Block down each time.
Ratchet Puller
Set Screw
Pull Block
Valve
Set Screw
Ram Section 24 inches
Coupling
Ram Section 36 inches
Set Screw
Pully Assembly
Stop Collar
Inflation Ram
Ram Removal Plate