Flashing 3x

Braking device is 
overloaded. 

 

Braking frequency is 
too high.

The specified max. braking 
frequency is exceeded.

Reduce braking current or 
braking frequency. 
During commissioning, 

 

5 braking operations in 
succession can be initiated 
without an overload being 
indicated.

Flashing 4x

Program- or 
controller-error

Program- or main-memory of 
the controller is defective.

If, after several disconnections 
from the mains voltage, the 
fault is still indicated, return the 
device to the producer.

Malfunction 
without fault 
indication

Braking current 
switches off, 
although the motor is 
still rotating

Braking time adjusted too short. Adjust a slightly higher braking 

time.

Braking current adjusted to a 
too small value.

Adjust a slightly higher braking 
time.

Motor cannot be 
started

After a braking interrupt, the 
contact on X3-X4 was not 
reclosed.

Make sure that the contact on 
X3-X4 is closed.

When switching the 
mains voltage on, 
the pre-fuses of the 
braking device blow

During braking, the power 
section ot the braking device 
became defective.

 

Possibly, after a mains reset 
caused by overload, the 
recovery time of 15 min was not 
waited out?

Return the device to the 
producer.

 

Important!

 Prior to installing a 

replacement device, it is 
absolutely necessary to check 
the contacts of the motor 
contactor (contact welding).

During braking, the 
pre-fuses of the 
braking device blow

Fuse rating of pre-fuses is too 
low.

Select fuse/s in compliance 
with the dimensioning rules.

During braking, the power 
section ot the braking device 
became defective.

 

Possibly, after a mains reset 
caused by overload, the 
recovery time of 15 min was not 
waited out?

Return the device to the 
producer.

 

Important!

 Prior to installing a 

replacement device, it is 
absolutely necessary to check 
the contacts of the motor 
contactor (contact welding).

When switching the 
motor on, the pre-
fuses of the braking 
device blow

During braking, the power 
section ot the braking device 
became defective.

 

Possibly, after a mains reset 
caused by overload, the 
recovery time of 15 min was not 
waited out?

Return the device to the 
producer.

 

Important!

 Prior to installing a 

replacement device, it is 
absolutely necessary to check 
the contacts of the motor 
contactor (contact welding).

Sporadic malfunction, for which there is no comprehensible explanation, may be caused 
by an EMC environment largely exceeding the permissible interference levels. The 
reason for this may be frequency inverters that are not interference-suppressed or a not 
optimal earthing concept.

Содержание VB 230-25LT

Страница 1: ...e l e c t r o n i c Quality is our Drive Braking Devices VB 230 400 6 25 30LT Assembly and Commissioning Instructions...

Страница 2: ...uts and outputs 8 8 1 Control input 8 8 2 Control outputs 9 9 Potentiometers 10 10 Technical data 11 10 1 Environmental conditions 11 11 Commissioning 12 11 1 Mounting instructions 12 11 2 Connection...

Страница 3: ...you see this sign always make sure that the device is de energized and secured against unintentional energizing These commissioning instructions were prepared with great care Nevertheless PETER elect...

Страница 4: ...tion and the trade associations apply in Germany The user must ensure that the drive turns into a safe operating state following a device failure in the event of maloperation or if the control unit ha...

Страница 5: ...er wear resistant and maintenance free for three phase asynchronous motors for mono phase motors retrofitting into existing plants possible integrated braking contactor automatic remanence time optimi...

Страница 6: ...directives 2014 30 EU 2014 35 EU 2011 65 EU This EC Declaration of Conformity is no longer valid if the product is modified or changed without our agreement This declaration is issued under the sole r...

Страница 7: ...tself the integrated braking relay pulls in After the contact bounce time has been waited out a controlled d c current is fed into the motor winding The magnetic field resulting from this has a brakin...

Страница 8: ...ge Faults occuring during braking are indicated via a flashing mode If the motor is to be restarted during a braking operation it is first of all necessary to stop the braking operation For this the c...

Страница 9: ...tor Opening of this contact for at least 150ms will cause a braking interrupt After closing of this contact however after 1200ms at the earliest the motor can be restarted Caution Danger to life throu...

Страница 10: ...in the case of star delta connections possible during braking to control the star contactor in order to interconnect the motor winding For more detailed information please see connection diagram under...

Страница 11: ...ses according to the diagram on page 9 the rated device current indicated on the rating plate is then not reached any more t Adapting the braking time The braking time can be adjusted within a range o...

Страница 12: ...currents 0 3 3A 2 12 5A 2 15A 0 3 3A 2 12 5A 2 15A Recommended for rated motor currents on IE3 Motors 0 3 2 5A 2 9A 2 12 5A 0 3 2 5A 2 9A 2 12 5A Rated device current 6A 25A 30A 6A 25A 30A c d f at m...

Страница 13: ...ntamination by water oil carbon deposits dust etc Warning Make sure that a minimum distance to adjoining devices is kept Above and underneath the housing a minimum distance of 50mm is to be kept 11 2...

Страница 14: ...rument Adjusting the braking current The braking current is to be adjusted so that the motor comes to a standstill within the time requested In this connection the braking current must not exceed 2 5...

Страница 15: ...the localization and correction of faults Continuance on the next page Fault indication on LED Ready Fault Possible cause Fault correction Flashing 2x Adjusted braking current was not reached Interru...

Страница 16: ...by overload the recovery time of 15 min was not waited out Return the device to the producer Important Prior to installing a replacement device it is absolutely necessary to check the contacts of the...

Страница 17: ...ally two types of fuse protection are available for the user 1 Fusing according to allocation type 1 DIN EN 60947 4 2 After a short circuit the braking device is allowed to be inoperative 2 Fusing acc...

Страница 18: ...to table 2 column 3 To protect the semiconductors it is necessary to select gR fuses featuring cutoff I t values of the ranges indicated in table 2 column 4 In this connection the fuse rating of the s...

Страница 19: ...per 80s 1 braking operation per 120s 1 braking operation per 220s 15A 5s 10s 15s 30s 1 braking operation per 25s 1 braking operation per 50s 1 braking operation per 75s 1 braking operation per 150s 1...

Страница 20: ...20 30 40 50 60 70 80 90 100 Cyclic duration factor in Permissible max braking current in of the rated device current Load vurve for VB 25 LT 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80...

Страница 21: ...Dimensions All dimensions indicated in mm Cyclicdurationfactor r c d f tB Cycletime 100 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Cyclic duration factor in Permissible max brak...

Страница 22: ...rs and susceptible electronic devices within a radius of 10m are subjected to interference If such interference which is definitely attributable to the operation of the braking devices VB occurs the e...

Страница 23: ...22 VB230 400 6 25 30LT...

Страница 24: ...VB230 400 6 25 30LT 23...

Страница 25: ...24 VB230 400 6 25 30LT...

Страница 26: ......

Отзывы: