![PESA Cougar 3 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/pesa/cougar-3/cougar-3_user-manual_1531791045.webp)
C
OUGAR
3
V
IDEO
R
OUTER
Publication 81-9059-0660-0, Rev. B
March 2011
Proprietary Information of PESA
5-10
Figure 5-5 Example Device Properties Display
5.8
SSC3
C
ONTROLLER
D
EVICE
P
ROPERTIES
D
ISPLAY
With the top-level SSC3 entry selected, the Device Properties window, Figure 5-6, displays controller
type and network communication parameters for the internal controller device(s): The upper area of
the window, labeled SSC3 Properties, is shown with muted fields and displays current status of
components of the small scale controller system. Entries in this field cannot be modified.
5.8.1
S
ETTING
SSC3
C
ONTROLLER
N
ETWORK
P
ARAMETERS
The lower area of the Device Properties Display, labeled IP Address, displays current network
parameters for the system controller. The SSSC3 device does not support DHCP protocol, and the
factory configured parameters are static until changed.
Factory configured IP address for the system controller:
•
SSC3 installed in primary controller slot - 192.168.1.203
•
SSC3 installed in secondary controller slot – 192.168.1.204
From the Devices Properties Display area you may enter new network parameters, including a new
Base IP Address for the controller devices by entering the new parameters in the active display fields.
The newly entered base IP address becomes the assigned address of the primary controller and the
secondary controller is assigned the address of Base IP+1. Click on Apply to apply the changes.