5
2.4.
Li-Po protection
Li-Po protection – enter programming mode for any selector position,
pull the trigger 10
times
, and hold the trigger until a sound signal can be heard to save the settings.
Batteries should never be discharged below certain level. Perun V3 offers a feature which
warns its user that his Li-Po battery is almost completely discharged and should be changed.
With Li-Po protection enabled, Perun will automatically detect number of Li-Po cells in
connected battery and if voltage for that number of will drop below safe limits, short sound
signals will be heard every 30 seconds.
2.5.
Double shot
Double shot – enter programming mode for any selector position,
pull the trigger 11 times
,
and hold the trigger until a sound signal can be heard to save the settings.
When double shot feature is enabled, if single fire mode is used, shots will be fired both
after the trigger has been pulled and relased.
2.6.
Calibration mode
Calibration mode - enter programming mode for any selector position,
pull the trigger 12
times
, and hold the trigger until a sound signal can be heard to save the settings.
Enabling this function will make Perun V3 enter calibration mode at next start-up. This
feature is meant mainly for technicians and more information about it can be found in
installation manual.