1 - TECHNICAL DATA
Power supply:
Autonomy:
Battery life after the
"battery low" symbol starts
flashing on the display:
White color backlight:
Type of action, disconnection and device:
Type of output:
Software:
Rated impulse voltage:
Cross-section of wires to terminals:
Input for remote contact ON/OFF:
Input for separate remote probe:
Type of insulation:
Degree of protection:
Pollution rating:
Number of temperature levels:
Ambient temperature display range:
Floor probe threshold display range:
External probe display range:
Relay ON signal:
Room temperature indicator resolution:
Temperature Set adjustment range (t1/t2/t3):
Setting temperature Set:
Temperature correction (Offset):
Antifreeze temperature: (t ):
Type of temperature adjustment:
- DIFFERENTIAL ON/OFF (default)
- Proportional with control period
Thermal gradient:
Temperature reading tolerance:
Operating temperature limits:
Storing temperature limits:
Reference regulations for CE markings:
n° 2
batteries 1,5 V type AA (LR6)
Alkaline
Approx. 2 years
Approx. 15 days
timed 6 sec. (default) / always off
1 / B / U / Electronic
voltage free relay with COM / NO / NC changeover contact,
max 5(3)A/250 V ~
class A
4 kV
1,5 mm ÷ 2,5 mm
2
2
for NO or NC contact free from potential
yes - probe may be set depending on use: remote, floor, external
class II
I 30
P
normal
n° 2 «
= COMFORT», «
= ECONOMY» + t antifreeze
t1
t2
- 5.0 °C ÷ + 37.7 °C (+ 23 °F ÷ +99.9 °F)
- 0.0 °C ÷ + 60.0 °C (+ 32 °F ÷ +140 °F)
- 9.9 °C ÷ + 60.0 °C ( +14.2 °F ÷ +140 °F)
0.1 °C (0.1 °F)
+5 °C ÷ +37.7 °C (+41.0°F ÷ +99.9 °F) limitable
adjustable by 0.1 °C / 0.1 °F sets
adjustable from -3.0 °C (5.4°F) to +3.0 °C (5.4°F) default 0.0 °C/0,0 °F
adju 5 °C ÷ <t2 (41,0 °F ÷ <t2) default 6 °C (42.8 °F)
adjustable from 0.2 °C to 1.2 °C (from 0,3 °F to 2.1 °F) default 0,3 °C (0,4°F)
cycles adjustable from 7 to 20 minutes (default 10 minutes)
max 1°K / 15 min
± 0,5°C (± 0,9°F)
0 °C ÷ +45 °C
-10 °C ÷ +60 °C
LVD - EMC EN60730-2-7 EN60730-2-9
Flashing + ON (winter) or + ON (summer)
ErP
classifica
energy
tion:
ErP Class I; 1% (Reg. EU 811/2013)
34