6.
Commissioning
and
operation
6.1
Potential
danger
When
it
starts
up,
the
pop
‐
up
sprinkler
rises
up
out
of
the
housing
and
builds
up
full
pressure
within
about
5
seconds.
The
jet
of
water
emitted
can
cause
injury.
For
this
reason
the
following
guidance
must
be
followed
when
commissioning
and
operating
the
sprinkler:
When
the
sprinkler
is
being
operated
in
automatic
mode,
there
must
be
nobody
present
in
the
area.
Operating
personnel
must
not
stand
in
the
direction
of
the
sprinkler's
jet
.
The
jet's
direction
is
marked
on
the
cover
by
an
arrow.
Figure
1
If
the
sprinkler
is
not
installed
flush
with
the
ground,
people
may
be
injured
by
a
fall
as
a
result
of
stumbling
or
tripping.
Therefore
check
prior
to
commissioning
and
regularly
during
ongoing
use
whether
the
sprinkler
cover
shuts
flush
with
the
surrounding
ground.
The
sprinkler
must
not
be
operated
without
a
closed
cover
for
the
cable
compartment.
During
operation
the
sprinkler
head
props
itself
against
the
edge
of
the
cover
and
cannot
rotate
freely
without
the
cover.
Jet
direction
Cover
for
cable
compartment