Construction

 

team

 

e

mail:

 

[email protected]

 

 

Cable

 

plan

 

(schematic

 

only)

 

 

 

 

Control

 

cable

 

specification:

 

Suitable

 

for

 

underground

 

installation

  

PVC

 

insulated

 

and

 

EPDM

 

sheated

 

cable,

 

NYY

 

For

 

VP3:

            

NYY

   

2x2.5mm

2

 

RE

 

 
 

For

 

further

 

details

 

please

 

see

 

separate

 

operating

 

instructions

 

for

 

Water

 

Control

  

(TDP072).

 

Содержание VP3 VAC

Страница 1: ...BAU CALW GmbH Industriestra e 19 29 D 75382 Althengstett Germany Tel 49 7051 162 0 Fax 49 7051 162 133 E mail perrot perrot de Construction team e mail technik perrot de Maintenance and Operating Inst...

Страница 2: ...S ON THE SIDE OF THE IRRIGATED AREA 5 4 INSTALLATION SCHEME FOR VP3 WITH RUBBER INFILL LAWN 9 5 4 1 HANDLING THE VP3 POP UP SPRINKLER WITH FILLED SYNTHETIC TURF 11 5 4 2 OPERATING INSTRUCTIONS FOR VP3...

Страница 3: ...operating instructions contain some fundamental instructions that must be followed when installing operating servicing and maintaining the sprinkler It is therefore imperative that these instructions...

Страница 4: ...tion of the pop up sprinkler by unauthorised personnel if the control unit is freely accessible Operation of the sprinkler with the sector to be watered wrongly set e g as the result of vandalism This...

Страница 5: ...il perrot perrot de Construction team e mail technik perrot de 3 Description 3 1 View from above 3 2 Side view Jet direction Cover for cable compartment Securing screw Manual ON OFF Auto control modul...

Страница 6: ...d replace retaining ring RT17844 VP3 valve lifter Remove valve RT25359 Face hole key Piston motor cover ZB98236 VP3 flush insert Flush main line RB25380 VP3 assembly key for nozzle Changing nozzle RB2...

Страница 7: ...njury Therefore make sure that the installation has been fully completed before turning on the water supply 5 2 Installation instructions The thread connection on the pop up sprinkler is 2 FT For the...

Страница 8: ...PE Hauptleitung dia PE Main Pipe 110 90 75 1 T St ck 90 110 x 4 IG T piece 90 110 x 4 FT ZH90159 1 T St ck 90 90 x 3 IG T piece 90 90 x 3 FT ZH90158 1 T St ck 90 75 x 2 IG T piece 90 75 x 2 FT ZH9015...

Страница 9: ...any Tel 49 7051 162 0 Fax 49 7051 162 133 E mail perrot perrot de Construction team e mail technik perrot de Sprinkler arrangement schematic only Detail X Sprinkler arrangement upon installation VP3 s...

Страница 10: ...Perrot REGNERBAU CALW GmbH Industriestra e 19 29 D 75382 Althengstett Germany Tel 49 7051 162 0 Fax 49 7051 162 133 E mail perrot perrot de Construction team e mail technik perrot de 5 4 Installation...

Страница 11: ...aft cover can be disassembled assembled see 8 6 Do not plug the drainage holes during adhesive bonding of the synthetic turf 5 4 2 Operating instructions for VP3 pop up sprinkler with filled synthetic...

Страница 12: ...e area to be watered The key operated switch gets fitted in a position from which the whole danger zone can be clearly seen Watering begins only when the operator gives the all clear by turning the ke...

Страница 13: ...or connecting the control cable to the coil fitted inside the sprinkler Open the cover of the cable compartment and attach cable connector Put back the cables into the cable compartment and close the...

Страница 14: ...Fax 49 7051 162 133 E mail perrot perrot de Construction team e mail technik perrot de Cable plan schematic only Control cable specification Suitable for underground installation PVC insulated and EP...

Страница 15: ...he sprinkler is being operated in automatic mode there must be nobody present in the area Operating personnel must not stand in the direction of the sprinkler s jet The jet s direction is marked on th...

Страница 16: ...t has no power c Slowly open supply of water to the sprinkler until operating pressure is built up It is possible that the sprinkler will briefly open but should then automatically close after at most...

Страница 17: ...arried out with the sprinkler running First fold out the safety catch to the side of the sprinkler head see illustration 2 so that no limbs e g fingers can get jammed if the sprinkler should unexpecte...

Страница 18: ...k perrot de 6 3 Setting the sector With this pop up sprinkler the sector setting is infinitely variable You can adjust the area to be watered by pulling on the relevant end of the top or bottom spring...

Страница 19: ...pring stop apart at both ends only to such extent that they can just be slid off If the spring stops get overextended it will not be possible to use them any more for back and forth operation Gently p...

Страница 20: ...g the regulating screw to the right reduces the rotational speed Option It is possible for the sprinkler to be completely stopped when the speed regulating screw is turned to the right If you turn it...

Страница 21: ...g If the sprinkler is taken back into use despite there still being ice in the piston chamber then at an ice temperature of approx 20 C it will take around 15 minutes until the drive is thawed out Ele...

Страница 22: ...approx 10Nm of torque That means with a lever length of 10cm you need to apply a force of 100N to the spanner Note After the third or fourth winter there should be no further expansion Marker points B...

Страница 23: ...r one year of use tighten the M6 flange screws 8 of them using a 10mm box spanner to ensure that the sprinkler module is fixed firmly in place Tightening torque 9 1 Nm Clean out the inside of the spri...

Страница 24: ...zle to be easily loosened by hand using the assembly key RB25189 and just as easily tightened again Wrong position Right position When fitting the nozzle make sure that the funnel gets pushed on in th...

Страница 25: ...out of the housing in order to carry out the repairs described below Unscrew cover using 5mm Allen key Remove the 8 flange screws using a 10mm box spanner Figure 6 Pull sprinkler module out of the ho...

Страница 26: ...alve insert can be slightly lubricated with oil or grease Insert the valve down into the guide housing by applying some gentle taps Using pliers RT17844 now fit the retaining ring into the groove prov...

Страница 27: ...ess back the mounting ring at the plug in connector and pull out the hose Fitting the control unit When buying a replacement part the control unit is supplied with plug and socket connections Push hos...

Страница 28: ...facturer Valve opens closes only with manual opening but not on any electric signal Screw for Manual opening is set to OFF Turn screw to the left as far as it will go to Auto Core is jammed in the coi...

Страница 29: ...conforms with the provisions of the directives indicated above The following harmonised standards were applied DIN EN 292 1 Safety of Machinery Basic terms general EN 12100 design principles part 1 G...

Отзывы: