e bunt.doc
Rev. 14.06.2010
Seite /
Page
34 / 40
Perrot REGNERBAU CALW GmbH
Industriestraße 19-27 / D-75382 Althengstett / Germany
Telefon : 0049-7051-162-0 / Fax : 0049-7051-162–133
E-mail : [email protected]
/ E-mail Konstruktion : [email protected]
8.3
Fitting coarse filter
Twist out flush insert.
Ensure that thread and O-ring are clean.
Lightly smear O-ring with acid-free grease.
Put coarse filter in place and manually tighten using coarse filter wrench.
8.4
Fitting the valve
Before fitting the valve, check the valve insert – especially around the valve seat
– for any dirt or damage!
Screw cleaned or new valve insert onto the valve lifter again and fit into the sprinkler
housing.
WARNING: Ensure it is fitted in the correct position!
Hollow screw
Entry for
hollow screw