background image

Care and Maintenance

Notes:

 Always switch the unit off and remove the power cord from the rear of the unit before attempting to 

clean your Audiant 100p Stereo Power Amplifier in the manner described below.

Never apply liquid directly to the unit.

Never use abrasives.

Never rub in a circular motion.

Front Panel and Cover

The front panel and cover feature a durable, high-quality anodised finish. To remove finger marks and dirt, 
simply rub the surface with a soft cloth.

If the dirt is not removed, use a small quantity of isopropyl alcohol on a clean cloth and rework the effected area.

Troubleshooting

There is no power

Ensure the AC power cord is connected securely. 
Ensure the mains plug is fully inserted into the wall socket and is switched on. 
Check the mains fuse of the unit. 
Check fuse in the mains plug or adaptor.

There is no sound

Check that the source component is properly connected. 
Check that the source component is playing.

There is no sound on one channel

Check interconnects.

There is a loud buzz or hum

Ensure no interconnects are loose or defective. 
Ensure that your tape deck/turntable is not too close to the amplifier.

There is weak bass or diffused stereo imaging

Ensure the speakers are wired in the correct polarity, the +ve terminal of the loudspeaker should connect to 
the +ve speaker output terminal of the amplifier, and likewise, -ve to -ve.

The Standby LED is flashing

The protection system of the amplifier has tripped and needs to be reset (see Protection System section).

10

Содержание Audiant 100p

Страница 1: ...Owners Manual Audiant 100p Stereo Power Amplifier...

Страница 2: ...plied with a non rewireable mains plug for the intended country Replacement mains leads can be obtained from your Perreaux dealer Should you need to change the plug please dispose of it carefully A pl...

Страница 3: ...r supply only of the type described in the operating instructions and or as marked on the rear of the unit DO NOT defeat the safety earth of the grounding type mains plug severe injury or death may re...

Страница 4: ...by any means electronic mechanical photocopying recording or otherwise without the prior written permission of the publisher The content of this manual is furnished for information use only is subjec...

Страница 5: ...the audio signal revealing the smallest details and exposing all of your music s hidden subtleties Our unique power isolation system uses a separate transformer secondary and filtered power supply to...

Страница 6: ...et will severely restrict heat dissipation Ensure that nothing is placed above or below the unit that might block or restrict the vents If the Audiant 100p has inadequate ventilation and or is played...

Страница 7: ...case always replace this fuse with another of the same type and rating 3 Mains Fuse The mains fuse is user serviceable and should always be replaced with the same type and rating see Technical Specifi...

Страница 8: ...ey should not be connected to the digital output of a CD player or any other digital device 7 Input Switch This switch is used to select the XLR balanced or RCA unbalanced inputs 8 Trigger Input The t...

Страница 9: ...Button switches the unit between Standby mode indicated by dim standby LED and On indicated by bright standby LED Standby is a low power mode where the power consumption is less than 1 Watt The unit...

Страница 10: ...low impedance or low sensitivity speakers Fuse Fail Detection The fuse fail detection system monitors the internal DC rail fuses If any of the fuses should fail output to the speakers is disconnected...

Страница 11: ...onnected securely Ensure the mains plug is fully inserted into the wall socket and is switched on Check the mains fuse of the unit Check fuse in the mains plug or adaptor There is no sound Check that...

Страница 12: ...Power Output per channel 0 1 THD N both channels driven 100Wrms into 8 145Wrms into 4 Total Harmonic Distortion THD N Typically 0 001 1kHz into 8 20Hz to 20kHz 0 02 into 8 Frequency Response 0 1dB 20H...

Страница 13: ...12 Physical Dimensions 431mm 17 0 67mm 2 6 286mm 11 3...