2
1…
7
01/2022
07/2022
360°
www.perma-tec.com
perma STAR CONTROL - Quick Start Guide
1. Predefi ne installation / Select lubricant, discharge connecting parts
2. Prepare lube-point
Clean lube-point
Remove grease fi tting
Add reducer, support fl ange
and tubes (if required)
For remote mounting:
Prefi ll lube-point and any grease lines / connections
(use the same grease that is contained in the lubrication system)
For direct mounting:
Prefi ll lube-point and any connecting parts
(use the same grease that is contained in the lubrication system)
3. Activation / Installation of lubrication system
Pressure check: Lube-point / all connecting parts
2022/01 · V
er
si
on: 1.2 · e
n
Select a suitable lubricant
for perma STAR LC unit
→ e. g. perma Multipurpose grease SF01
Select discharge period
→ e. g. with perma SELECT APP
(refer to our product catalog for details)
Possible mounting positions:
(Oil fi lled LC
+/- 45°)
Assemble drive
and LC
Tighten threaded ring hand tight until
the white triangle is completely visible
Note activation /
exchange date
on label
Confi guration can be
found on the back page
Remove plug
Connect the cable to the
drive by screwing it on
Remove cap and screw
the lubrication system into
the lubrication point
Reducer
Remote mounting fo
r lube-points with vibration,
limited mounting space, high temperature
Direct mounting
Examples: Bearing lubrication
Mounting bracket
STAR Standard Duty
1-point G1/4 female
(109663)
Hose connector G1/4 male for
hose iØ 9.5 mm - push-lock
(101554)
Heavy Duty hose up to
+100 °C oØ 16 mm x iØ 9.5 mm
(101555)
Hose connector G1/4 male for
hose iØ 9.5 mm - push-lock
(101554)
Support fl ange STAR
G1/4 male x G1/4 female
(109420)
Support fl ange STAR
Reducer
Add sealant
(e. g.
Loctite® 243™)