PREPARING THE SPACE

Make  sure  that  the  space  that  the  opening  where  the  Perlick 
cabinet(s)  is/are  to  be  installed  is  properly  prepared.  Refer  to 
Figures 1 and 2 (page 5) and Figures 3 and 4 (page 6) to ensure 
proper space dimensions and electrical service are correct for the 
model to be installed.

CAUTION

If cabinet is being installed under a countertop it is recommended 

that the countertop be supported by structure other than the 

refrigerated cabinet to prevent damage to the counter top.

IMPORTANT  NOTE:

  For  a  cabinet  door  to  operate  properly,  the 

door must open a minimum of 90°. Use a minimum 3-inch filler 
in  corner  installations  to  assure  a  90°  door  opening.  Allow  24” 
clearance in front of the unit for full door swing, shelf pull-out or 
drawer pull-out. 

IMPORTANT  NOTE:

  Make  sure  the  floor  under  the  unit  is  level 

with  the  surrounding  finished  floor.  Protect  a  finished  floor  with 
plywood, cardboard or some other suitable material before moving 
the unit into place. Failure to do this may result in damage to the 
floor.

PREPARING ELECTRICAL CONNECTIONS

A 115 volt, 60Hz, 15 amp circuit breaker and electrical supply are 
required. A separate circuit is required for each Perlick unit installed.

Follow the National Electrical Code and local codes and ordinances 
when installing the receptacle.

All Perlick units come equipped with a NEMA 5-15P 90° plug with 
a  minimum  of  5-feet  of  cord  extending  beyond  the  rear  of  the 
cabinet. The electrical outlet must be flush with or recessed into 
the back wall.

IMPORTANT  NOTE:

  Never  use  an  extension  cord  to  extend  the 

power cord to the electrical receptacle.

DANGER

ELECTROCUTION HAZARD

Electrical grounding is required. This appliance is equipped with 

a  three  prong  (grounding)  polarized  plug  for  your  protection 

against possible shock hazards.

• 

Never remove the round grounding prong from the plug.

• 

Never use a two-prong grounding adapter.

• 

Never use extension cords to connect power to the unit.

Where  a  two-prong  wall  receptacle  is  encountered  or  a  longer 
power  cord  is  required,  contact  a  qualified  electrician  to  have  it 
replaced in accordance with applicable electrical cords.

DANGER

Failure to comply with the above electrical guidelines may result 

in possible injury, death, fire or loss of property.

UNPACKING AND MOVING

CAUTION

Do  not  cut  cardboard  sleeve  covering  the  unit.  Cutting  may 

result in damage to the exterior of the cabinet. 

1. Uncrate the unit outside on a flat surface. Remove the card-

board sleeve by removing the banding holding the sleeve to 
the shipping base. Carefully lift the cardboard sleeve up over 
the top of the unit. 

2. Carefully lift unit off base and onto a hand truck or dolly (this 

should be done with a minimum of two people; larger units 
may require additional helpers!). Make sure the unit is bal-
anced on transporting device using soft, flexible strapping. 
Protect unit surfaces with cloth material where strapping 
contacts unit. 

3. Before moving unit, secure door to unit with tape to the door 

closed. 

4. Carefully move unit to installation site and place in front of 

opening. 

WARNING

A minimum of two people should lift the cabinet off the base to 

prevent possible personal injury.

Содержание HP24BS

Страница 1: ...Luxury Operation Installation Manual Signature Series HP24 and HP48 inch models Form No Z2340 Rev 06 04 2012 HP24FS HP24RS HP24BS HP24WS HP48RR HP48RB HP48WO HP48WW Excludes Beer Dispenser Models...

Страница 2: ......

Страница 3: ...of this manual The information will help you quickly identify a problem and get it remedied In the event you require assistance please contact the dealer where you purchased your unit WARRANTY REGIST...

Страница 4: ...onths can cause the unit to malfunction This could void the warranty Never install the unit behind closed doors Be sure front louvered toe plate is free of obstruction Obstructing the airflow can caus...

Страница 5: ...door swing 11 4 Min clearance from a corner to acheive 90 door swing 6 1 4 11 7 8 18 3 16 20 50 Area in which electrical outlet must be located 79 16 41 4 Lowest shelf location 31 2 213 8 15 8 269 16...

Страница 6: ...13 16 Inside drawer Top Bottom 24 with 1 16 tolerance 1 1 4 Min clearance from a corner to acheive 90 door swing 24 15 16 Min clearance for door swing 44 20 5 8 6 3 8 11 3 4 22 12 1 4 50 Area in which...

Страница 7: ...utlet must be flush with or recessed into the back wall IMPORTANT NOTE Never use an extension cord to extend the power cord to the electrical receptacle DANGER ELECTROCUTION HAZARD Electrical groundin...

Страница 8: ...sary hardware is supplied with the unit The anti tip brackets when properly installed should secure the rear legs and prevent the unit from tipping forward Some installation sites may require modifica...

Страница 9: ...nd more than 3 4 from bottom of the unit 4 Slide cabinet into position Make sure the rear levelling legs slide under the anti tip brackets Push the unit into the open ing until the bottom front edge o...

Страница 10: ...step for an additional five wine bottles Single Door Beverage Center The single door unit comes with two full extension black vinyl coated wine racks and one Industry Exclusive full extension black v...

Страница 11: ...1 C 1 3 SW THIS DOCUMENT PUBLICATION SOFTWARE DRAWING CONTAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY FORM ELECTRONIC...

Страница 12: ...or 48 units provided entire until is ordered with drawers Like shelving drawers are full extension To remove drawers 1 Pull the drawer out to its farthest point 2 Locate the tabs in the middle on both...

Страница 13: ...t least 3 4 thick The solid wood overlay panel should not weight more than 20 pounds The glass wood overlay panel should not weight more than 10 pounds The following instructions cover installing a so...

Страница 14: ...14 Operation Installation Manual Signature Series HP24 and HP48 models Figure 13 Solid wood overlay panel template...

Страница 15: ...15 Operation Installation Manual Signature Series HP24 and HP48 models Figure 14 Glass wood overlay panel template...

Страница 16: ...16 Operation Installation Manual Signature Series HP24 and HP48 models Figure 15 Wood overlay drawer panel template...

Страница 17: ...17 Operation Installation Manual Signature Series HP24 and HP48 models Figure 16 Lock installation solid wood overlay door panel...

Страница 18: ...18 Operation Installation Manual Signature Series HP24 and HP48 models Figure 17 Lock installation wood overlay glass door panel...

Страница 19: ...19 Operation Installation Manual Signature Series HP24 and HP48 models Figure 18 Lock installation wood overlay drawer panel...

Страница 20: ...d overlay panel at marked locations taking care not to damage the wood overlay panel 3 Countersink screw heads so screw heads are flush with back side of panel Attach handle to overlay panel CAUTION P...

Страница 21: ...ates when the door is open The cabinet also comes standard with a manual light switch located next to the light for displaying your products through a glass door Always ensure that the manual switch i...

Страница 22: ...22 Operation Installation Manual Signature Series HP24 and HP48 models TEMPERATURE CONTROLLER 2011 24 48 72 Cabinet Installation Operation Manual Document No Z2305 27...

Страница 23: ...eft 45 F 40 F to 68 F Wine Reserve Right 55 F 40 F to 68 F IMPORTANT NOTE All mutli zone units must have a minimum of 8 F difference between zones CHECKING PRODUCT TEMPERATURE To accurately check the...

Страница 24: ...gure 6 Remove the toe plate and use a soft bristle brush and vacuum to remove the dust and lint Avoid damaging or crushing the condenser fins or tubing Upon completion reinstall the toe plate CAUTION...

Страница 25: ...and free of obstructions Has the door been open for a long time or more frequent door openings occured Are the internal louvers and fan guard openings obstructed Has warm product been placed in the c...

Страница 26: ...PERLICK RESIDENTIAL REFRIGERATION PRODUCTS LIMITED WARRANTY excludes H50IM Clear Ice Makers see warranty on page 31 ENTIRE PRODUCT Full Three Year Warranty For three 3 years from date of original purc...

Страница 27: ...of any other warranty expressed or implied including but not limited to any implied warranty of merchantability or fitness for a particular purpose provided however that to the extent required by law...

Страница 28: ...or service and the name of the nearest Perlick authorized service representative contact your Perlick dealer distributor or Perlick Corporation s Customer Service Department 8300 West Good Hope Road M...

Отзывы: