background image

Form No. Z2280

3

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Preparing the Cabinet for Use

– 

Direct Draw Dispensers Self-Contained

Parts List

Faucet Standard.

Faucet Head Assembly.

Black Connector Hose 

3

16

” x 3’.

5

16

” Air Hose.

Spanner Wrench.

Bag of Miscellaneous Parts.

Suggested Tools Required

#2 Phillips Screwdriver.

Spanner Wrench (included).

#10 Crescent Wrench.

9

/

16

” Allen Wrench.

5

/

16

” & 

3

/

8

” Nut driver.

Power driver.

Uncrating and Inspection

Remove all crating material before operating.
Carefully inspect cabinet for hidden damage. If
damage is discovered, file your claim immediately
with the transportation company. Perlick is
not responsible for damage in transit.

Placing the Cabinet

Push the cabinet into place using rollers when 
necessary. Important: Proper air flow around the
condensing unit is necessary for efficient operation.
Never obstruct the air flow in and out of the 
condensing unit.

Leveling the Cabinet

When the cabinet is in place, check installation with
a carpenter’s level. A slight pitch to the drain side is
desired. Water may accumulate if the cabinet is
pitched to the opposite side.

Installing Casters or Legs (Optional)

Attach casters to the cabinet bottom in the holes
provided. Use supplied 

1

/

4

”- 20 x 

3

/

4

” hex head 

self-tapping machine screws. Use power driver if
available.

Installing the Faucet and
Dispensing Head

Before you begin: Wash tapping devices and
faucet. Flush beer, tapping device and faucet lines
with fresh water.

Apply RTV around the base of the dispensing 
head to seal it to the top. Align the dispensing 
head over the holes on the cabinet top and use 
screws provided to secure standard to cabinet 
top. Wipe off excess RTV to complete the seal.

Attach faucet to standard using spanner 
wrench to tighten coupling. Attach faucet 
handle to faucet. 

Insert flexible plastic air hose six to seven 
inches into bottom of faucet standard. 
Secure hose with tie wrap (supplied).

Plumbing

The floor drain in the right rear corner is equipped
with a 

3

/

4

” female pipe thread connection with side or

bottom access for beer drainer waste.

Remove either side or bottom drain plug with an 
allen wrench and attach a 

3

/

4

” male pipe (provided

by plumber) to an external drain connection.

Evaporator condensate has been plumbed to a 
condensate pan located in the compressor housing.
CAUTION:

Do not overtighten drain fitting 
as it may damage the threads.

NOTE: The end of the CO

2

line extends through a 

sleeve on the side of the cabinet in the 
machinery compartment. Connect this 
line to the pressure supply with a hose 
and fitting.

Electrical

The cabinet must be connected to a separately
fused power source (see electrical specification
plate) and grounded in accordance with National
and Local Electrical Codes. Caution: Do not
attempt to operate the equipment on any other
power source than that listed on the Electrical
Specification plate.

WARNING!

To avoid compressor damage,after returning 
cabinet to an upright position, let unit stand for 
24 hours before plugging it in and running the unit.

Содержание DP32

Страница 1: ... 558 5592 E Mail Perlick Perlick com www Perlick com MODEL NOS DS Series IMPORTANT INFORMATION Fill out the enclosed warranty card and mail to the Perlick Corporation to register the warranty If the card is not returned the warranty period will begin from the date the equipment is shipped from the factory This manual has been prepared to assist you in the installation of your Direct Draw Dispenser...

Страница 2: ...High strength polyethylene Door pan and ceiling High strength polystyrene Floor pan Satinless steel Walls Galvanized steel EXTERIOR All Models The top is 20 gauge stainless steel The back front and sides are stainless steel Bottom is 18 gauge galvanized steel Black Models Doors and grilles are black vinyl coated steel Stainless Models Doors and grilles are stainless steel REFRIGERATION R 134a capi...

Страница 3: ...ping devices and faucet Flush beer tapping device and faucet lines with fresh water Apply RTV around the base of the dispensing head to seal it to the top Align the dispensing head over the holes on the cabinet top and use screws provided to secure standard to cabinet top Wipe off excess RTV to complete the seal Attach faucet to standard using spanner wrench to tighten coupling Attach faucet handl...

Страница 4: ...of black beer line connector hose and thread onto top of keg coupler Hand tighten Place clamp on one end of red air line Push end over air valve located inside cabinet Tighten clamp with screwdriver Turn shut off valve to OFF horizontal position Place clamp on the other end of red air line and push over tailpiece on coupler Tighten clamp with screwdriver CAUTION Do not use keg coupler as a handle ...

Страница 5: ... Replace carbonic washer Part No 157F2P if needed and reattach regulator to filled cylinder Turn CO2 hand valve counterclockwise until fully open Turn regulator shut off valve to open position Adjust CO2 gas flow as required turning clockwise for higher pressure Proper CO2 Handling ALWAYS Connect a regulator reducing valve to CO2 cylinder Secure cylinder in upright position whether in storage or i...

Страница 6: ...maintain a storage temperature of 36 41 degrees F The control is factory set at 38 degrees F Adjusting the temperature The temperature control is inside the cabinet on the right hand side of the evaporator fan panel assembly You will need a screwdriver to turn the adjusting screw Make small adjustments until the desired temperature is achieved Colder Temperatures Turn the adjusting screw clockwise...

Страница 7: ...beer from the fermentation process When the temperature of draft beer exceeds 50 a process of secondary fermentation may take place The beer faucet may exhibit a white colored substance yeast build up if not cleaned on a regular basis Beer Stone All beer contains calcium which is present from the grains used in the brewing process it is an important natural material in draft systems in that as it ...

Страница 8: ...n glass Place the glass at a 45 angle one inch below faucet Do not let the glass touch the faucet Open the faucet all the way STEP 1 Let the remaining beer run straight down the middle of the glass This ensures proper release of CO2 by producing a 3 4 to 1 foam head STEP 3 After the glass has reached half full gradually bring the glass to the upright position STEP 2 Close the faucet quickly and co...

Страница 9: ...e CO2 pressure is too low due to leak or pressure setting CO2 is turned off at night Cooler is too cold CO2 leak or defective sticking check valve Sluggish CO2 regulator Cloudy Beer Beer in glass appears hazy not clear CAUSES Dirty glass Dirty faucet or beer line Frozen or nearly frozen beer Old beer Beer that has not been refrigerated for a long period of time Beer and CO2 Facts Keg No of No of N...

Страница 10: ...r fan guard 65557 65557 65557 Temperature control 61283 61283 61283 Bulb clamp C6634 C6634 C6634 Wire harness compressor bottom 65560 65560 65560 Wire harness evaporator 65561 65561 65561 Lock 63762 63762 36762 Space lock 63761 1 63761 1 63761 1 Lock rail 65432 24SS 65432 24SS 65432 24SS Grille rail 65432 12SS 65432 12SS 65432 12SS Condenser pan 65565 1 65565 1 65565 1 Condenser end panel 66215 1S...

Страница 11: ...0 2P Ball 4 43641 1 Ball retainer 5 31087 2P Probe washer 6 31089 O Ring 3 per assembly 7 43061 Body 8 23682 2P Check valve 9 157R2P Washer 10 206B 1 Tailpiece 11 2026 Coupling nut 12 31088 2P Bottom seal washer 13 31084 1 Retaining screw 14 43002A Yoke assembly w lock 15 43001A Yoke assembly standard 16 32474 1 Wrench Miscellaneous Part No Description 157L2P Beer line connector gasket 57F2P CO2 t...

Страница 12: ...ck is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice Wiring Diagram Direct Draw Dispensers Self Contained BLACK BLACK POWER CONNECTION JUNCTION BOX CONDENSING UNIT WHITE RED GREEN BLACK WHITE GREEN BLACK THERMOSTAT WHITE EVAPORATOR FAN EVAPORATOR FAN CAPPED NOT USED 12 DS Series 2 3 and 4 Keg Coolers ...

Отзывы: