background image

V2.0

Floating Wall Mounted Shelf Instruction Manual

Model: 

PSDSK2-1

Thank you for choosing this PERLESMITH product! At 
PERLESMITH we strive to provide you with the best quality 
products and services in the industry. Should you have any issues, 
please don't hesitate to contact us at

Technical Support:
1-800-556-6806 Mon-Fri 8am - 8pm(CST)
Other Info:
[email protected](US)
[email protected](CA)

Содержание PSDSK2-1

Страница 1: ...LESMITH product At PERLESMITH we strive to provide you with the best quality products and services in the industry Should you have any issues please don t hesitate to contact us at Technical Support 1 800 556 6806 Mon Fri 8am 8pm CST Other Info supportus perlesmith com US supportca perlesmith com CA ...

Страница 2: ...If you require replacement parts contact customer service at supportus perlesmith com US supportca perlesmith com CA Do not attempt to install or assemble this product if the product or hardware is damaged or missing The included hardware is designed for use on vertical walls constructed of wood studs or concrete A wood stud wall is defined as consisting of a minimum of 2x4 wooden studs 2 width by ...

Страница 3: ...the lag screws W A 1 Tighten the lag screws W A 1 only until the washers W A 2 are pulled firmly against the wall plate Ensure the wall plate A is securely fastened to the wall before continuing to the next step D C B A X1 Glass Shelf Support G X2 Plug H Connector E X4 X2 X2 X2 X2 X2 X4 Pad Pad F1 W A 1 Shelf Kits Wall Kits Bolt M5x8mm Allen Key x1 x2 Lag Screw Cable manager Wall plate End cap Glas...

Страница 4: ...2 W A 1 Avoid potential personal injury or property damage DO NOT over tighten the lag screws W A 1 Tighten the lag screws W A 1 only until the washers W A 2 are pulled firmly against the wall plate A Ensure the wall plate is securely fastened to the wall before continuing to the next step Any material covering the wall must not exceed 5 8 in 16 mm Mount the wall plate A directly onto the concrete ...

Страница 5: ...te A to concrete wall using lag screws W A 1 and washers W A 2 by phillips screwdriver A 1 2 INSTALL THE TEMPERED GLASS G S A E S B UP UP UP UP 1 8 in 3mm W A 1 W A 2 Connect the connector E to glass shelf support G with bolts S A and Allen key S B as shown in the Fig 2 1 and keep about 1 8in 3mm spacing left between the connector with glass shelf support as shown in the Fig 2 2 W B Fig 2 1 Fig 2 ...

Страница 6: ...shelf support G along the wall plate rail at the desired height respectively Firmly tighten the bolts S A with Allen key S B UP UP C G S B S C Note DO NOT overtighten Tighten only until snug Note The tempered glass base is designed to show the shiny glass side facing up UP CAUTION Secure the glass shelf to the lower glass shelf support at first then secure the topper shelf one ...

Страница 7: ...ps and plugs into the wall plate 3B 3 Manage the cables along with the cable manager 3A 1 3A 2 3A 3 3A 1 Manage the cables along with the cable manager 3A 2 Add one of the end caps to the bottom of the wall plate then insert the cable manager with cables into the wall plate 3A 3 Add end caps and plugs into the wall plate UP UP Not Included Not Included UP UP UP ...

Страница 8: ...happy with your product as we designing and manufacturing it for you We strive to provide you with the best quality products and services in the industry If you have any questions please don t hesitate to contact us at Technical Support 1 800 556 6806 Mon Fri 8am 8pm CST Other Info supportus perlesmith com US supportca perlesmith com CA ...

Отзывы: