Troubleshooting 

General 

 

Ensure power is supplied to the media converter. 

 

Ensure both devices on either end of the fiber are compatible. 
If using a single fiber connection, ensure that you have both 
an Upstream (U) and Downstream (D) media converter. 

 

Ensure all cabling is of the correct type and is in good 
operating condition. 

 

For dual-stranded fiber connections, ensure the RX and TX 
has been reversed between the 2 media converters.  

No connectivity 

If unable to get full connectivity with all DIP switches in the UP 
position, the following procedure is recommended for 
troubleshooting. 

Method 1 

1. 

Set the Link mode to Standard (SW3 – Down) on both media 

converters. Leave all other switches in the Up position. 

2. 

Connect the near end device to the copper connection. The 

LKC LED indicates good copper connection. If the LKC LED 
is not lit, then check the copper cable and the attached 
device. 

3. 

Repeat for the far end media converter. 

4. 

Connect the fiber cable to both media converters.  The LKF 

LED indicates good fiber connection. If no LKF LED then 
check the fiber cabling. 

5. 

Return units to desired configuration. 

Method 2: 

The fiber connection can also be verified by configuring the 
remote media converter for loopback mode. The LKF LEDs on 
both media converters should be lit. Data should pass through the 
local converter, over the fiber connection to the remote media 
converter. At the remote media converter, the data will be looped 
back and passed through the fiber, once again, to pass through 
the local converter to the copper link. 
 

Содержание SR-100 Series

Страница 1: ...P N 5500443 10 Rev F Perle Fast Ethernet Media Converters Installation Guide SR 100 XXXXXX XT SR 100 SFP XT...

Страница 2: ...r take note notes contain helpful suggestions Caution Means reader be careful In this situation you might perform an action that could result in equipment damage or loss of data Warning IMPORTANT SAFE...

Страница 3: ...70 Limited Power Supply LPS according to EN IEC 60950 1 Limited energy circuit according to EN IEC 61010 1 Warning If this equipment is used in a manner not specified by the manufacturer the protectio...

Страница 4: ...00 are also available in Extended Temperature models Model Connector Mode Distance Wavelength SR 100 SC2 XT SC MM 2 km 1 25 mi 1310 nm SR 100 ST2 XT ST MM 2 km 1 25 mi 1310 nm SR 100 SC2U SC MM 2 km 1...

Страница 5: ...km 50 mi 1590 1550 nm SR 100 SC120 SC SM 120 km 74 6 mi 1550 nm SR 100 ST120 ST SM 120 km 74 6 mi 1550 nm SR 100 SFP XT SFP Note 1 Note 1 Fiber characteristics will depend on the SFP fiber module sele...

Страница 6: ...tch settings optional 3 Install and connect the fiber cable 4 Install and connect the copper cable 5 Power up the media converter Accessing the DIP Switches To access the DIP switches 1 Disconnect the...

Страница 7: ...nstallation Guide 7 DIP Switches Set the DIP Switches accordingly and then slide the case together until you hear an audible click 1 Reserved 2 Auto Negotiation 3 Smart Link Pass Through 4 Far End Fau...

Страница 8: ...Full Duplex mode Smart Link Pass Through Switch 3 Switch Position Mode Up default Enable Down Disable Enable In this mode the link state on one connection is directly reflected through the media conv...

Страница 9: ...If the media converter has been set to Link Pass Through mode the effect will be the same as FEF since the link loss on the fiber receiver will bring down the copper link which will in turn cause the...

Страница 10: ...so that the attached device near end can negotiate its Ethernet parameters as if it was negotiating directly with the far end device The Pause switch setting on the media converter should match the ca...

Страница 11: ...nnections Connect the fiber cables from one media converter to the other media converter switch fiber device ensuring that the RX and TX are reversed at the opposite end Installing the Simplex Fiber C...

Страница 12: ...ings must be used Use copper conductors only 1 Ensure the power source is off prior to connection 2 Strip both 12 20AWG wires 7 8 mm 5 16th 3 Loosen the terminal block screws and connect positive nega...

Страница 13: ...he unit is in loopback mode Blinking slowly the unit has a hardware error LKF Fiber Link Activity On Fiber link present Blinking quickly Fiber link present and receiving data Blinking slowly Fiber lin...

Страница 14: ...or crossover and automatically configures the connection Error Recovery In certain configurations and under specific conditions where the media converter brings down a link to convey status there is...

Страница 15: ...own on both media converters Leave all other switches in the Up position 2 Connect the near end device to the copper connection The LKC LED indicates good copper connection If the LKC LED is not lit t...

Страница 16: ...ing Storage Humidity 5 to 95 non condensing Operating Altitude Up to 3 048 m 10 000 ft Weight 0 12kg Dimensions SC 114 x 100 x 22 5 mm ST 126 x 100 x 22 5 mm SFP 117 x 100 x 22 5 mm Safety UL ULC EN 6...

Страница 17: ...ST2D MM TX 1550 RX 1310 Min 20 Max 12 Min 31 Max 14 11 SR 100 SC20 XT MM TX 1310 RX 1310 Min 18 Max 7 Min 32 Max 3 14 SR 100 ST20 XT MM TX 1310 RX 1310 Min 15 Max 8 Min 32 Max 3 17 SR 100 SC20U XT SM...

Страница 18: ...TX 1550 RX 1550 Min 0 Max 5 Min 35 Max 0 35 Fiber Cabling Requirements MM 50 125 microns or 62 5 125 microns SM 9 125 microns Ethernet Copper Cabling Requirements Category 5e UTP or STP Straight thro...

Страница 19: ...Perle SR 100 Fast Ethernet Media Converter Installation Guide 19 Mechanical Drawings...

Страница 20: ...wards the rail This will snap the bottom hooks of the DIN Rail clip onto the bottom of the DIN rail Removing the SR 100 from the DIN Rail The DIN Rail attachment clip has a slot at the bottom of the l...

Страница 21: ...reate an electrical connection 3 Install the media converter onto the DIN Rail overtop one of the TBUS connections ensuring that the TBUS extension connects into the media converters TBUS slot 4 Repea...

Страница 22: ...tes uses and can radiate radio frequency energy and if not installed and used in accordance with this hardware guide may cause harmful interference to radio communications Operation of this equipment...

Отзывы: