![Perle SMI-10GT Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/perle/smi-10gt/smi-10gt_manual_1530491006.webp)
Firmware download
Update the latest level firmware for management and media
converter modules via TFTP or PerleVIEW.
Power
10GT to SFP
10GT to XFP
Input Supply
Voltage
12 vDC Nominal
Maximum
Power
Consumption
(watts)
SMI-10GT: 13
SMI-10GRT: 16*
18*
Power
Connector
5.5mm x 9.5mm x 2.1mm barrel socket
Power Adapter
Universal
AC/DC Adapter
100-240v AC, regulated AC/12v DC adapter included
Indicators
Power / TST
On: Power indication and in normal operation
Blinking slowly: the unit is in loopback or test mode (either port)
Red solid: the unit has a hardware error (upon power up)
Red and blinking: the unit has a hardware error specified by combination of LK1
and LK2
LK1 (SFP/XFP)
On: Link present
Blinking quickly: Fiber link present and receiving data.(including test data)
Blinking slowly: Fiber link disabled because the other fiber link went down.
Blinking 1 sec on 3 sec off – module shut down due to high temperature.
Off: No fiber link present or no module inserted
LK2
On: 10GBase-T link present
Blinking quickly: Link present and receiving data
Blinking slowly: Link disabled because Link 1 went down
Off: 10GBase-T link is not active
Switches - accessible through a side opening in the chassis
Link Mode
When the Link Mode is enabled (default), each port will reflect the state of its port peer
using Smart Link Pass-Through. In this mode, if a link loss is detected on one port, the
transmit signal on the other port is disabled “passing through” the state of the failed link.
This enables managed switches and other devices to report link failures to their network
NMS.
When the switch is in the down position, Smart Link Pass-Through is disabled. If a link
loss is detected on one port, the transmit signal remains enabled on the other port.