Perle S-110-P Скачать руководство пользователя страница 21

 

Perle PoE/PoE+ 10/100 Ethernet Media Converter  

 Installation Guide

  

 

 
21

 

Compliance Information  

FCC 

This product has been found to comply with the limits for a Class A 
digital device, pursuant to Part 15 of the FCC rules. These limits 
are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in 
accordance with the instructions in this Guide, may cause harmful 
interference to radio communications. Operation of this equipment 
in a residential area is likely to cause harmful interference, in 
which case the user will be required to correct the interference at 
his/her own expense. 

EN 55022, Class A  

WARNING This is a Class A product. In a domestic environment 
this product may cause radio interference in which case the user 
may be required to take adequate measures. 

EN 55024, Class A  

Laser Safety – IEC 60825-1:2007 

This product meets Class I Laser safety requirements per IEC-
60825-1:2007 standard and complies with FDA/CDRH 21 
CFR1040.10 and 21CFR1040.11. 

WARNING: Visible and invisible laser radiation may be present 
when cables are not connected. Do not stare into the beam or 
view the beam directly with optical instruments. Failure to observe 
this warning could result in an eye injury or blindness. 

WARNING: Use of controls, adjustments or the performance of 
procedures other than those specified herein may result in 
hazardous radiation exposure. 

Содержание S-110-P

Страница 1: ...P N 5500318 12 Perle PoE PoE 10 100 Ethernet Media Converters Installation Guide S 110P S 110PP S 110P SFP S 110PP SFP...

Страница 2: ...compatible with Powered Devices that comply with both the IEEE 802 3af and the 802at 2009 standards The fiber connection can be either single mode SM or multimode MM and can operate over different wa...

Страница 3: ...r cable 5 Install and connect the copper cable 6 Install the Power cord Relief clip optional 7 Power up the media converter Power Sourcing Pinouts When Power Sourcing is enabled on a copper port the S...

Страница 4: ...outs will work for most installations as 802 3a and 802at 2009 POE POE devices will detect and sync to the correct POE option However in the rare case that you need to modify the settings the procedur...

Страница 5: ...5 DIP Switches The DIP switches for Bank 1 are accessible through the opening in the side of the enclosure Bank 1 Bank 2 To access the DIP switches for Bank 2 unscrew the six side screws on the case a...

Страница 6: ...does not support Auto negotiation and fixed settings are required by the copper link partner Auto When enabled the media converter will negotiate with its link partner to determine the most optimal p...

Страница 7: ...converter If the installation has a media converter on both ends of the fiber link and both are set up for Link Pass Through then a loss of copper link on the far end device will propagate through bot...

Страница 8: ...EF and the local media converter is set up with Link Pass Through a loss of fiber link on either the transmit or receive line will be passed through to the local copper connection thus notifying the c...

Страница 9: ...d the loss of fiber link has no effect on PSE power to the PD device Enabled When enabled if the media converter detects loss of link on the fiber port it will turn off PSE output power to the PD devi...

Страница 10: ...ter will force the speed to 10 Mbps Duplex Copper Switch 2 Switch Position Copper port Up default Full Duplex Down Half Duplex Full Duplex In the Up switch position the media converter will be set to...

Страница 11: ...iber module and insert the SFP into the opening on the front of the media converter 2 Ensure the SFP module is properly seated The release latch of the SPF fiber transceiver must be in the closed up p...

Страница 12: ...he other media converter switch fiber device Installing the Copper Cable Locate 10 100Base T compliant copper cables with the appropriate connectors Connect the RJ 45 cable between the Perle media con...

Страница 13: ...Guide 13 5 Plug the other end of the power cord into an appropriate power outlet Powering up the Perle Media Converter Connect the Perle supplied power adapter to the media converter Connect the powe...

Страница 14: ...is applied to the unit Blinking slow Loopback mode fiber interface is in loopback mode Blinking fast Power On failure See LED Pattern to determine pattern combination and failure cause LED Pattern LKF...

Страница 15: ...ted a compliant PD and is applying power over UTP Solid Orange Inactive The PSE is not active The PSE has been configured to provide power however a compliant PD not detected no power applied a PSE ha...

Страница 16: ...matically configures the connection Pause IEEE 802 3xy Integrated Pause signalling is an IEEE feature that temporarily suspends data transmission between two devices in the event that one of the devic...

Страница 17: ...1 1 Set the Link Pass Through mode to Standard on both media converters Leave all other switches in the Up position 2 Connect the copper device to the copper port on the media converter The LKC LED l...

Страница 18: ...h the S 110P If the PD is a POE device then a POE media converter must be used S 110PP Ensure that the power supply being used is the one provided with the product If the PD does not support Alternati...

Страница 19: ...220 hours 81 386 hours 1 SC ST 1 copper 385 526 hours 214 161 hours 79 404 hours Fiber Optic Specifications PoE P PoE PP Mode Wavelength nm TX Power dB RX Power dB Budget dB S 110P M2xxC2 S 110PP M2x...

Страница 20: ...40U S 110PP S1SC40U SM TX 1310 RX 1550 Min 8 Max 3 Min 33 Max 3 25 S 110P S1SC40D S 110PP S1SC40D SM TX 1550 RX 1310 Min 8 Max 3 Min 33 Max 3 25 S 110P SFP S 110PP SFP SFP Note 1 Note 1 Note 1 Note 1...

Страница 21: ...e in which case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio i...

Страница 22: ...ound at http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Su...

Отзывы: