Perle S-110-P Скачать руководство пользователя страница 17

 

Perle PoE/PoE+ 10/100 Ethernet Media Converter  

 Installation Guide

  

 

 
17

 

Troubleshooting

 

General 

 

Ensure power is supplied to the media converter. Only the 
Perle provided power supply may be used. 

 

Ensure the remote device’s fiber connection type is 
compatible with the media converter.  If using a simplex fiber 
connection, ensure that you have both an Upstream (U) and 
Downstream (D) media converter. 

 

Ensure all cabling is of the correct type and is in good working 
order. 

 

For duplex fiber connections, ensure the RX and TX has been 
reversed between the two media converters.  

No connectivity 

If unable to get full connectivity with all DIP switches in the UP 
position, this procedure is recommended for troubleshooting. 

Method 1 

1.  Set the Link Pass-Through mode to Standard on both media 

converters. Leave all other switches in the Up position. 

2.  Connect the copper device to the copper port on the media 

converter. The LKC LED light indicates good copper 
connection. If the LKC LED is not lit, then check the copper 
cable and the attached device. 

3.  Repeat for the far end media converter. 

4.  Connect the fiber cable to both media converters. The LKF 

LED indicates good fiber connection. If no LKF LED then 
check the fiber cabling. Ensure the transmitter and receiver 
pairs are crossed. 

5.  Return units to desired configuration. 

Method 2: 

The fiber connection can also be verified by configuring the remote 
media converter for loopback mode. The LKF LEDs on both media 
converters should be lit. Data should pass through the local 
converter, over the fiber connection to the remote media 
converter. At the remote media converter, the data will be looped 

Содержание S-110-P

Страница 1: ...P N 5500318 12 Perle PoE PoE 10 100 Ethernet Media Converters Installation Guide S 110P S 110PP S 110P SFP S 110PP SFP...

Страница 2: ...compatible with Powered Devices that comply with both the IEEE 802 3af and the 802at 2009 standards The fiber connection can be either single mode SM or multimode MM and can operate over different wa...

Страница 3: ...r cable 5 Install and connect the copper cable 6 Install the Power cord Relief clip optional 7 Power up the media converter Power Sourcing Pinouts When Power Sourcing is enabled on a copper port the S...

Страница 4: ...outs will work for most installations as 802 3a and 802at 2009 POE POE devices will detect and sync to the correct POE option However in the rare case that you need to modify the settings the procedur...

Страница 5: ...5 DIP Switches The DIP switches for Bank 1 are accessible through the opening in the side of the enclosure Bank 1 Bank 2 To access the DIP switches for Bank 2 unscrew the six side screws on the case a...

Страница 6: ...does not support Auto negotiation and fixed settings are required by the copper link partner Auto When enabled the media converter will negotiate with its link partner to determine the most optimal p...

Страница 7: ...converter If the installation has a media converter on both ends of the fiber link and both are set up for Link Pass Through then a loss of copper link on the far end device will propagate through bot...

Страница 8: ...EF and the local media converter is set up with Link Pass Through a loss of fiber link on either the transmit or receive line will be passed through to the local copper connection thus notifying the c...

Страница 9: ...d the loss of fiber link has no effect on PSE power to the PD device Enabled When enabled if the media converter detects loss of link on the fiber port it will turn off PSE output power to the PD devi...

Страница 10: ...ter will force the speed to 10 Mbps Duplex Copper Switch 2 Switch Position Copper port Up default Full Duplex Down Half Duplex Full Duplex In the Up switch position the media converter will be set to...

Страница 11: ...iber module and insert the SFP into the opening on the front of the media converter 2 Ensure the SFP module is properly seated The release latch of the SPF fiber transceiver must be in the closed up p...

Страница 12: ...he other media converter switch fiber device Installing the Copper Cable Locate 10 100Base T compliant copper cables with the appropriate connectors Connect the RJ 45 cable between the Perle media con...

Страница 13: ...Guide 13 5 Plug the other end of the power cord into an appropriate power outlet Powering up the Perle Media Converter Connect the Perle supplied power adapter to the media converter Connect the powe...

Страница 14: ...is applied to the unit Blinking slow Loopback mode fiber interface is in loopback mode Blinking fast Power On failure See LED Pattern to determine pattern combination and failure cause LED Pattern LKF...

Страница 15: ...ted a compliant PD and is applying power over UTP Solid Orange Inactive The PSE is not active The PSE has been configured to provide power however a compliant PD not detected no power applied a PSE ha...

Страница 16: ...matically configures the connection Pause IEEE 802 3xy Integrated Pause signalling is an IEEE feature that temporarily suspends data transmission between two devices in the event that one of the devic...

Страница 17: ...1 1 Set the Link Pass Through mode to Standard on both media converters Leave all other switches in the Up position 2 Connect the copper device to the copper port on the media converter The LKC LED l...

Страница 18: ...h the S 110P If the PD is a POE device then a POE media converter must be used S 110PP Ensure that the power supply being used is the one provided with the product If the PD does not support Alternati...

Страница 19: ...220 hours 81 386 hours 1 SC ST 1 copper 385 526 hours 214 161 hours 79 404 hours Fiber Optic Specifications PoE P PoE PP Mode Wavelength nm TX Power dB RX Power dB Budget dB S 110P M2xxC2 S 110PP M2x...

Страница 20: ...40U S 110PP S1SC40U SM TX 1310 RX 1550 Min 8 Max 3 Min 33 Max 3 25 S 110P S1SC40D S 110PP S1SC40D SM TX 1550 RX 1310 Min 8 Max 3 Min 33 Max 3 25 S 110P SFP S 110PP SFP SFP Note 1 Note 1 Note 1 Note 1...

Страница 21: ...e in which case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio i...

Страница 22: ...ound at http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Su...

Отзывы: