![Perle PERLE P850 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/perle/perle-p850/perle-p850_user-and-system-administration-manual_1530555016.webp)
Installation
10
Setting the Link Interface Type
(Universal WAN only)
The Universal WAN Interface must be configured to match the service
to which it will be connected.
WARNING: ensure that the connector cable used with the Universal
interface module has the correct pinouts for the operational mode
selected for the interface (V.11/X.21, V.35, RS232/V.24, or
RS530/RS422). Using the incorrect cable connector for the operational
mode selected may cause permanent damage to the interface module.
Please see Appendix D for pinout assignments.
Set Link Interface Type:
Location:
Main
ª
Configuration
ª
WAN Set Up
ª
Link Set Up
ª
Link Interface Type
Select the Service type to which this P850 router will be
connected.
Note:
If the module is being changed from one type of service to
another, you must first select “none” before a new selection
may be chosen. Also the link must be toggled through a
disable/enable cycle before the change is brought into effect.