background image

IDS-509FPP Hardware Installation Guide

PoE Managed Industrial Ethernet Switches

Updated: November 2017

Version A1.11.24.2017

Document Part#:5500387-10(Rev I)

www.perle.com

Содержание IDS-509FPP

Страница 1: ...IDS 509FPP Hardware Installation Guide PoE Managed Industrial Ethernet Switches Updated November 2017 Version A1 11 24 2017 Document Part 5500387 10 Rev I www perle com ...

Страница 2: ...ference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this hardware guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct th...

Страница 3: ...S switch 13 Connecting Power to the IDS Switch 13 Wiring the Relay Alarm 14 Wiring Digital Inputs 14 Connecting the Console Port 15 Connecting Data Ports 17 Resetting the Switch 17 Configuring the IDS Switch 20 Appendix A Technical Specifications 21 Appendix B Sample Labels 25 Appendix C Mechanical Drawings 26 Appendix D DIN Rail and Wall Mounting 28 Appendix E IDS Maintenance 30 Appendix F Cables...

Страница 4: ...witch with attached DIN rail mounting bracket Quick Start Guide Document Conventions This document contains the following conventions Most text is presented in the typeface used in this paragraph Other typefaces are used to help you identify certain types of information The other typefaces are Note Means reader take note notes contain helpful suggestions Caution Means reader be careful In this sit...

Страница 5: ...guide For more details and for the most up to date list of models please refer to the product pages at www perle com XXXXXXX represents fiber ports of different wavelengths distances and connectors Standard Models 10 100 1000Base T Ethernet Ports 10 100 1000 Base T Ports Ethernet PoE Enabled Fiber Ports 100 Temp IDS 509F2PP6 XXXXXXX 1 6 2 Standard IDS 509F3PP6 XXXXXXX 0 6 3 Standard IDS 509F2PP6 X...

Страница 6: ...er 1 2 8 SD card slot 2 Status LEDs 9 Terminal Block for Digital Inputs Relays 3 Console Port serial 10 Reset FS 4 Console Port USB 11 100Base X Fiber ports 5 DIP switches 12 Fiber status 6 10 100 1000Base T Ethernet Port 13 Wall Mount Bracket Screw Holes 7 10 100 1000Base T Ethernet Ports with PoE PoE capability 14 DIN Rail Clip ...

Страница 7: ... for Power 1 2 7 10 100 1000Base T Ethernet Ports with PoE PoE capability 2 Status LEDs 8 SD card slot 3 Console Port serial 9 Terminal Block for Digital Inputs Relays 4 Console Port USB 10 Reset FS 5 DIP switches 11 Fiber status 6 100Base X Fiber port 12 Wall Mount Bracket Screw Holes 13 DIN Rail Clip ...

Страница 8: ...Description Green blinking after power on System booting Green solid System ready operating normally Green blinking slowly Fast Setup Mode activated port available Green blinking fast Fast Setup Mode activated no port available Red Hardware fault or firmware load error State Description Off No alarms configured Green solid Alarms configured but no alarms detected Red solid Alarm condition detected...

Страница 9: ...ion State Description Off Ring Master not activated Green solid Ring Master Active redundant port blocked Coupling Link enabled Green flashing Ring Master unable to establish a ring due to missing link on one of the Ring ports Yellow solid Ring Master Active redundant port unblocked indicates a break in the Ring ...

Страница 10: ...switch management function using the industry standard CLI command set This port has an RJ 45 connector See RJ 45 Console Port Pinouts USB Console Port The MicroUSB port is an alternative connection to the switch s console This provides access to the switch management function using the industry standard CLI command set When connected the port presents a serial interface that can be used from a PC...

Страница 11: ...reen and Yellow LEDs Fiber Port Status Indicators Port Link State Description Green 1000 Mbps Green Yellow 100 Mbps Yellow 10 Mbps On solid Port Link Random blinking Port Link and Activity Slow blinking Error disabled Rapid blinking Port in Fast Setup Mode State Description Green Link Green Flashing Link Activity ...

Страница 12: ...re Installation Guide 10 Terminal Block Connectors P1 Power Input 1 P2 Power Input 2 IN 1 Digital Input 1 Dry Contact IN 2 Digital Input 2 Wet Contact R Relay with 2 connection points Normally Open NO Normally Closed NC ...

Страница 13: ...ad during system boot up If a DIP switch is changed the IDS switch must be rebooted in order for the change to take effect DIP Switch Ring Feature SW1 SW2 Ring Role Coupling Mode Description On On Software control Ring Master functionality is controlled by software configuration On Off Master Primary Ring Feature enabled Ring Role Master Coupling Active on Port 4 Note 1 Off On Client Standby Ring ...

Страница 14: ...oltage inputs are designed for operation with Safety extra low Voltage SELV Connect only to SELV circuits with voltage restrictions in line with IEC EN 60950 1 Hazardous Location Warnings Warning This equipment shall be installed in an enclosure that provides a degree of protection not less then IP54 in accordance with EN 60079 15 and accessible only by the use of a tool Warning The equipment shal...

Страница 15: ...nal grounding follow this procedure Grounding the chassis requires the following items One grounding lug not provided One 12AWG wire not provided Follow the manufacturers instructions for attaching the ground wire to the grounding lug Attach the grounding lug to the chassis and secure with the grounding screw provided Connecting Power to the IDS Switch The IDS switch has two power inputs that can ...

Страница 16: ...stallations failure to remove the power from the source prior to completing the wiring connections to the alarm relay could cause an electrical arc resulting in a possible explosion Wiring Digital Inputs The IDS switch has two digital input connections one to sense to Dry Contact and one to sense a Wet Contact IN1 This can sense a dry contact On this terminal pair the IDS switch provides a voltage...

Страница 17: ...S switch console port RJ45 and the other end of the cable to a COM port onyour PC 2 Choose Start Control Panel Systems or equivalent on the WindowsOperating Sys tem you are using 3 Click the Hardware tab and choose Device Manager Expand the Ports COM LPT section This will expand the drop down to show the number of com ports on your sys tem Connect the cable to one of these ports probably com1 or c...

Страница 18: ...xpand the Ports section The assigned COM port appears can be identified 4 Start an terminal emulation program such as Putty or SecureCRT on the com port where you have connect the cable to the PC 5 Configure your COM port within the emulation program on the PC as 9600 baud 8 data bits 1 stop bit No parity None flow control 6 The PC will display the boot loader sequence 7 Press Enter to display the...

Страница 19: ...10 100 or 1000 Mb s link to the switch See LED Indicators for moredetails Note It may take a few seconds for the device to become active By default the IDS switch will have Rapid Spanning Tree RSTP protocol enabled This protocol will first check the network for any cabling loops prior to bringing the port up in order to prevent network disruptions Fiber Connections To connect to 100Base X follow t...

Страница 20: ... passwords and security certificates are deleted The start up and backup software are unaffected Follow this procedure Power off the switch Press and hold the reset button While continuing to hold the reset button apply power to the switch ALR LED will go on after power up when it goes out release the reset button The switch is now reset to factory default configuration Booting the Switch When fir...

Страница 21: ...are shipped in Factory default mode Refer to the Quick Start Guide that came with the switch for instructions on how to connect to the switch for the first time Password Recovery When the switch is not in factory default the Fast Setup Mode sequence will activate Password recovery Note The password recovery feature can be disabled in the software LED Behavior PWR Press and hold the Reset FS button...

Страница 22: ...n Web Device Manager The Perle Web Device Manager is an embedded Web based application that provides an easy to use browser interface for managing the switch This interface provides the ability to configure and manage the switch This is accessible through any standard desktop web browser Requires the switch to have a valid IP address Fast Setup This utility provides the ability to do either an ini...

Страница 23: ...nal 44 57 VDC PoE 802 3af or IEEE 802 3at type 1 5 5A Max Alarm Relay NO Normally Open NC Normally Closed con tacts 1 0A 24VDC or 0 5A 48VDC Requires Class 2 LPS or SELV circuit with Fuse protection Digital Input IN1 Connects to Dry Contact Circuit Provides 12V 36mA On 2 1mA 4K Ohms Off 1 2mA 9K Ohms Digital Input IN2 Connect to Wet Contact Circuit requires external power Input Voltage Rating 36 t...

Страница 24: ...X in a variety of wavelengths distances and connectors Console port RJ45 DTE serial port MicroUSB Type B female port serial interface Switch properties Standards IEEE 802 3 for 10Base T IEEE 802 3u for 100Base TX IEEE 802 3ab for 1000Base T IEEE 802 3x for Flow Control IEEE 802 3af or IEEE 802 3at type 1 Environmental Specifications Operating Temperature Ranges IDS 509FPP IDS 509FPP XT 10 C to 60 ...

Страница 25: ...act discharge 4kV Air Discharge 8kV IEC EN 61000 4 3 RS 20Vm 80Mhz 1GHz 10Vm 1 4GHz 2GHz 2GHz 5Vm 2GHz 2 7GHz IEC EN 61000 4 4 EFT DC power line 2kV I O 1kV IEC EN 61000 4 5 Surge DC power line Line Line 1 1kV Line Earth 1 1kV Data Line line earth 1 1kV IEC EN 61000 4 6 CS 150Hz to 80 MHz 10Vrms IEC EN 61000 4 8 Magnetic Field 30 A m EN 61000 6 2 2005 AC 2005 IEC 61000 6 2 2005 General Immunity in...

Страница 26: ...for the Perle Technical Assistance Center PTAC can be found at the link below www perle com support_services support_request shtml Warranty Registration This product is covered by the Perle Ethernet Switches Warranty Details can be found at https www perle com support_services warranty shtml ...

Страница 27: ...IDS 509FPP Hardware Installation Guide 25 Appendix B Sample Labels ...

Страница 28: ...IDS 509FPP Hardware Installation Guide 26 Appendix C Mechanical Drawings ...

Страница 29: ...IDS 509FPP Hardware Installation Guide 27 ...

Страница 30: ...f the DIN rail cliponto the bottom of the DIN rail See diagram below Removing the IDS from the DIN Rail 1 The DIN rail attachment clip has a slot at the bottom of the latch that is visible beneath the switch when it is mounted 2 Insert a flat blade screwdriver into the slot and twist the base to release the clip Alter natively a downward force on the clip will release the clip 3 When the clip is r...

Страница 31: ...llow roomfor sliding the wall mount panel between the wall and the screws 5 Once the screws are fixed to the wall insert the four screw heads through the large parts of the keyhole shaped screw openings 6 Pull the IDS switch down to lock the IDS switch to the wall mount 7 Tighten the four screws securely to the wall Note for best results use screws with the following attributes Head diameter 5 6 m...

Страница 32: ... 2 inches on all sides of the IDS switch to pro vide proper airflowthrough the unit Do not use solvents or cleaning agents on this unit Keep vent holes clear of debris If case gets dirty wipe with a dry cloth Ensure all cables are in good working condition Replace any frayed cables or cables without clips ...

Страница 33: ...thernet enabled devices These Ethernet ports will automatically adjust depend ing on the type of Ethernet cable used straight through or cross over and the type of device NIC type or HUB Switch type connected to the port Requirements Cat 5 UTP or STP Cat 5e cables 24 22 AWG 0 20mm2 0 33mm2 Straight through or Ethernet Crossover cable Note An optional cable adapter is available to provide RJ45 to D...

Страница 34: ...onnector Multimode 50 125 or 62 5 125 micron fiber cable Single mode 9 125 micron fiber cable Simplex BIDI single strand SC or ST connector Multimode 50 125 or 62 5 125 micron fiber cable Single mode 9 125 micron fiber cable Ethnernet Connector 8 pin RJ 45 Fiber Connections ...

Страница 35: ...802 3af Type 1 and IEEE 802at 2009 Type 2 standards For PoE devices up to 15 4 watts per port For PoE devices up to 30 watts per port Connect the copper cables from each TP port RJ45 on the IDS 509PP switch to compliant Powered Devices PDs See below for RJ 45 pinouts for PoE PoE ports ...

Отзывы: