IDS-105G Installation Guide
- 15 -
Ethernet Copper Cabling Requirements
•
Category 5 UTP or STP
•
24-22 AWG
•
Straight through or Ethernet crossover cable
Connect the copper cables from each TP port (RJ-45) on the IDS-
105G switch to Ethernet-enabled devices. See below for pinouts.
8-pin RJ-45
Remaining pins not used.
Fiber Port Cabling Requirements
MM:
50/125 microns or 62.5/125 microns
SM:
9/125 microns
Connect the fiber cables to Port 6/7 on the IDS-105G and the
other end to a compliant fiber devices. If you are making your own
fiber cables, remember that the RX on one side needs to go to TX
on the other side and vice versa. See diagram below.
RX
TX
RX
TX