background image

 

 

 

 

Copyright 2022 Perle Systems Ltd.

 

  Page 2 

 

All Rights Reserved 

IDS-105FE & IDS-104FE Series Ethernet Switch    

Installation Guide

 

IDS-105FE & IDS-104FE Series Ethernet Switch

 

IDS-105FE & IDS-104FE  
11/08/2022 

Data Connection 

10/100Base-TX Connections 

The following lists the pinouts of 10/100Base-TX 

ports: 

Pin  Regular Port 

Uplink Port 

Input Receive Data + 

Output Transmit Data 

Input Receive Data - 

Output Transmit Data 

Output Transmit Data +  Input Receive Data + 

NC 

NC 

NC 

NC 

Output Transmit Data -  Input Receive Data - 

NC 

NC 

NC 

NC 

 

100Base-FX Connections 

The Tx (transmit) port of device I is 

connected to the Rx (receive) port of 

device II, and the Rx  (receive) port 

of device I to the Tx (transmit) port 

of device II. 
 
 
 
 
 
 
 

Features and Specifications 

 

 

Complies with EN 61000-6-2 & EN 61000-6-4 

EMC Generic standard immunity for industrial 

environment. 

 

Supports IEEE802.3az 10Base-Te only. 

10Base-T is not supported. 10Base-Te is fully 

interoperable with 10Base-T over 100m of 

class D (Category 5) or better cabling as 

specified in ISO/IEC 11801:1995. 

 

Supports 802.3az/802.3u/802.3x. Auto-

negotiation: 10/100Mbps, Full/Half-duplex. 

Auto MDI/MDIX. 

 

100Base-FX: Multi mode SC or ST type, Single 

mode SC or ST type. 

 

100Base-BX: WDM Multi mode or Single mode 

SC type. 

 

Supports 1024 MAC addresses, 448K bits 

buffer memory. 

 

IEEE802.3x Flow control for Full-duplex, Back 

pressure for Half-duplex. 

 

Non-blocking architecture and full wire-

speed forwarding rate. 

 

Supports IEEE802.1p QoS with two priority 

queues. 

 

Supports IEEE802.3az Energy Efficient 

Ethernet (EEE). 

 

Supports Max. length of frame up to 1552 

Bytes. 

 

Power Consumption: 1.82W Max. 0.14A @ 

12VDC, 0.07A @ 24VDC, 0.038A @ 48VDC. 

 

Power Supply: DC Terminal Block power 

input, 12-48VDC. 

 

Operating temperature ranges from -10 to 

60°C (14 to 140°F). 

 

Plastic compact DIN-Rail industrial case 

design. 

 

Provides 4kV surge protection. 

 

Installation 

Assembly

: Place the device on the DIN rail from 

above using the slot. Push the front of the device 

toward the mounting surface until it audibly 

snaps into place. 

Startup

: Connect the supply voltage to start up 

the device via the terminal block.  

Dismantling

: Pull out the lower edge and then 

remove the device from the DIN rail. 
 

 

 

 

Отзывы: