Appendix D - DIN Rail and Wall Mounting 34
IDS-509-SFP Hardware Installation Guide
Appendix D - DIN Rail and Wall Mounting
This appendix provides instruction on the following:
•
Mounting the IDS Switch on a DIN Rail
•
Removing the IDS from the DIN Rail
•
Wall Mounting the IDS
Mounting the IDS Switch on a DIN Rail
1. The DIN rail clip will be fixed to the back of the IDS unit when you receive the switch.
2. Position the IDS switch such that the top hooks of the DIN rail clip attach onto the top
of the DIN rail.
3. Rotate the bottom of the IDS switch towards the rail. This will snap the bottom hooks
of the DIN rail clip onto the bottom of the DIN rail.
See diagram below
Removing the IDS from the DIN Rail
1. The DIN rail attachment clip has a slot at the bottom of the latch that is visible beneath
the switch when it is mounted.
2. Insert a flat blade screwdriver into the slot and twist the base to release the clip. Alter
-
natively a downward force on the clip will release the clip.
3. When the clip is released, pull the bottom of the switch out slightly and remove the
switch from the DIN rail.