Perle 05051890 Скачать руководство пользователя страница 22

 

 

Perle 10/100/1000 Media Converter Module – Installation Guide

   

22

Fiber Cabling Requirements 

MM:   50/125 microns or 62.5/125 microns 

SM:   9/125 microns 

Ethernet Copper Cabling Requirements 

  Category 5 UTP or STP 

  24-22 AWG 

  Straight through or Ethernet crossover 

Compliance Information  

 

 
FCC 
 

This product has been found to comply with the limits for a Class A digital device, 
pursuant to Part 15 of the FCC rules. These limits are designed to provide 
reasonable protection against harmful interference when the equipment is operated 
in a commercial environment. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with the 
instructions in this Guide, may cause harmful interference to radio communications. 
Operation of this equipment in a residential area is likely to cause harmful 
interference, in which case the user will be required to correct the interference at 
his/her own expense. 

EN 55022, Class A  

 
WARNING

 

This is a Class A product. In a domestic environment this product may 

cause radio interference in which case the user may be required to take adequate 
measures. 
 
 

EN 55024, Class A  


 

Laser Safety – IEC 60825-1:2007 

This product meets Class I Laser safety requirements per IEC-60825-1:2007 
standard and complies with FDA/CDRH 21 CFR1040.10 and 21 CFR1040.11. 
WARNING: Visible and invisible laser radiation may be present when cables are 
not connected. Do not stare into the beam or view the beam directly with optical 
instruments. Failure to observe this warning could result in an eye injury or 
blindness. 
WARNING: Use of controls, adjustments or the performance of procedures other 
than those specified herein may result in hazardous radiation exposure. 

 

Содержание 05051890

Страница 1: ...N 5500308 20 Rev B Perle 10 100 1000 Ethernet Media Converter Module Installation Guide C 1110 XXXXX Unmanaged Module CM 1110 XXXXX Managed Module C 1110 SFP Unmanaged Module CM 1110 SFP Managed Modul...

Страница 2: ...nt wavelengths and distances depending on the model selected see table below Model Connector xx Mode Distance Wavelength C 1110 M2xx05 CM 1110 M2xx05 SC ST LC MM 550 m 1804 ft 850 850 nm C 1110 M1SC05...

Страница 3: ...80D CM 1110 S1SC80D SC SM 80 km 50 mi 1590 1510 nm C 1110 S2xx120 CM 1110 S2xx120 SC ST LC SM 120 km 75 mi 1550 1550 nm C 1110 S1SC120U CM 1110 S1SC120U SC SM 120 km 75 mi 1510 1590 nm C 1110 S1SC120D...

Страница 4: ...setting Optional 3 Set the Auto Config jumper CM 1110 only optional 4 Set the DIP switch settings optional 5 Set the SGMII Interface support if your SFP has a SGMII Interface 6 Insert the Media Conver...

Страница 5: ...the module in SW mode and strapping pins 2 and 3 will set it in Auto Config mode Auto When set to Auto the module will at power up check its internal flash memory to see if configuration information...

Страница 6: ...ough the software management interface See details below C Model Hardware only To set SGMII Interface support on a C 1110 module strap pins 1 and 2 on jumper J5 see diagram below CM Model Software onl...

Страница 7: ...nverter Module will negotiate with its link partner to determine the most optimal parameters for this connection The C 1110 and CM 1110 will advertise capabilities of 10 100 and 1000 Mbps full and hal...

Страница 8: ...f link is lost on one of the connections then the other link will be brought down by the Media Converter Module With Media Converters on both ends of the fiber link and both setup for Link Pass Throug...

Страница 9: ...s notifying the connected device If the Media Converter has been set to Smart Link Pass Through mode the effect will be the same as FFA since the link loss on the fiber receiver will result in bringin...

Страница 10: ...r Switch 4 Switch Position Mode Up default Full Down Half Note When Auto Negotiation SW1 is set to Off the Media Converter will use this Duplex setting for its copper connection Up The Media Converter...

Страница 11: ...another Perle Media Converter this parameter should be set to Auto The Media Converter Module will advertise 1000Mbps Full and Half Duplex no Pause Down The Media Converter Module s fiber will be fix...

Страница 12: ...tion Observe electrostatic discharge precautions when installing the Media Converter Module s into the Chassis Failure to observe this caution could result in damage to the Media Converter Module s an...

Страница 13: ...captive retainer screw to ensure the Media Converter Module is locked in place 7 Remove the dust cap from the fiber connector and connect the fiber and copper cables Removing Media Converter Modules L...

Страница 14: ...a 1000Base X compliant duplex 2 strands fiber cable with appropriate connectors Connect the fiber cables from the Media Converter to the other Media Converter switch fiber device ensuring that the RX...

Страница 15: ...ompliant copper cables with male RJ 45 connectors installed at both ends Connect the RJ 45 cable between the Perle Media Converter Module and the device Note The Perle Media Converter Module supports...

Страница 16: ...x Mode Off Half Duplex Mode LKF fiber On Fiber link is present Off No fiber link present Blinking slow Copper link down but fiber link appears functional Blinking fast Fiber link is up and receiving d...

Страница 17: ...re the Media Converter Module brings down a link to convey status there is potential for a deadlock Recovery is achieved by momentarily restoring the link to see if the original failure has been resol...

Страница 18: ...RX and TX has been reversed between the two Media Converters No connectivity If unable to get full connectivity with all DIP switches in the UP position these methods are recommended for troubleshoot...

Страница 19: ...rs to their desired configuration Method 2 Configure the remote Media Converter for loopback mode The LKF LEDs on both Media Converters Modules should be lit Data should pass through the local convert...

Страница 20: ...3 7 5 C 1110 M1SC05U CM 1110 M1SC05U MM TX 1310 RX 1550 Min 8 Max 0 Min 8 Max 0 10 C 1110 M1SC05D CM 1110 M1SC05D MM TX 1550 RX 1310 Min 8 Max 0 Min 8 Max 0 10 C 1110 M2xx2 CM 1110 M2xx2 MM TX 1310 RX...

Страница 21: ...0 S2ST70 CM 1110 S2ST70 SM TX 1550 RX 1550 Min 2 Max 5 Min 23 Max 3 21 C 1110 S2LC70 CM 1110 S2LC70 SM TX 1550 RX 1550 Min 0 Max 5 Min 23 Max 3 23 C 1110 S1SC80U CM 1110 S1SC80U SM TX 1510 RX 1590 Min...

Страница 22: ...ons Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense EN 55022 Class...

Страница 23: ...at http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Suppor...

Отзывы: