Chapter 3
35943
Page 12
How to stop the engine
1. Remove the load from the engine and allow the engine to cool for 2-3 minutes.
2. Switch the engine stop switch to the stop position, refer to the users’ handbook of the application
manufacturer.
Adjustment of the engine speed range
The idle or the maximum speed settings must not be changed by the engine operator, because this can
damage the engine or generator. The warranty of the engine can be affected if the seals on the fuel injection
pump are broken during the warranty period by a person who is not approved by Perkins.
Running-in
A gradual running-in of a new engine is not necessary. Prolonged operation at light loads during the early life
of the engine can cause lubricating oil to enter the exhaust system. Maximum load can be applied to a new
engine as soon as the engine is put into service and the coolant temperature has reached a minimum of 60°
C (140° F).
The engine will benefit if the load is applied as soon as possible after the engine is put into service.
Cautions:
•
Do not operate the engine at high speeds without a load.
•
Do not overload the engine.
Relay for an insulated negative earth
Note:
This relay is available from Wimborne Marine Power Centre as an option.
The battery negative cable (A1) connects to the stud (A2) on the negative earth relay (A4). This grounds
the electrics to earth, through terminal (A5) connected through the mounting bracket (A3), while starting the
engine or operating glow plugs, if they are fitted.
Angle of operation
The 700GM can operate at 25o contiuous or 35o intermittent in all directions.
Содержание 35943
Страница 1: ...User s Handbook 700GM GB Part No 35943...
Страница 2: ......
Страница 4: ...Title 35943...
Страница 12: ...Chapter 1 35943 Page 6...
Страница 16: ...Chapter 2 35943 Page 10...
Страница 36: ...Chapter 4 35943 Page 30...
Страница 40: ...Chapter 5 35943 Page 34...
Страница 48: ...Chapter 9 35943 Page 42...