Proper installation of your Cascade pump will help ensure years of trouble free service.

1.  Position the pump as near to the water and as low as is practical.  This will help reduce the time to reach full 

    flow,  

           avoid cavitation, and maximize your pumps performance.  

2.  Minimize friction loss by using the appropriate diameter pipe determined by gallons per minute flow, 

  

reducing run length, and minimizing the number of elbows and fittings as much as possible.

3.  Maximize your pumps service life by protecting the motor from the elements by ensuring it is well covered 

     and adequately ventilated.

  

 

 

       Exposing your pump to excessive heat or moisture will shorten the life of the motor. 

4.       

  

Protect the motor against dirt, water, and all foreign matter.  If the motor has been flooded,  

do not operate it until it has been checked by an authorized motor technician and has been found to be  

safe to operate. If the motor is damaged by dirt, moisture, foreign matter or corrosion it is not covered by the

warranty.

5.  Mount the motor to a stable base where it will not get submerged. Use caution when installing in a vault. 

        Be sure proper drainage is in place to prevent flooding. A sturdy pedestal under the pump is beneficial 

        in a vault application to maximize height above the ground. Ensure the vault is properly ventilated.

 6.  The Cascade series pump ports are 1.5” NPT on both the inlet and discharge ports. The 1.5” NPT ports may be

 

    

                   

connected with fittings available from PerformancePro Pumps (MPF-215) or standard 1.5” NPT PVC fittings  

    

                    

available at your local hardware store and should be connected to PVC or flex pipe plumbing.  

                                         

All plumbing lines should be well supported and properly aligned.  This will prevent undue stress to the

   housing and fittings. Use a good primer and PVC cement to glue pipe connections.   

   

                       

7.  Installations in which the water level is elevated above the pump it is highly recommended to use a 

  

ball or swing type check valve to prevent back flow and possible reverse rotation. A ball valve will 

supplement a swing check valve and allow flow adjustments. 

8. FILL THE PUMP HOUSING AND ENTIRE SUCTION LINE WITH 

                                                                       WATER BEFORE STARTING THE PUMP.

General 

Before Installation

Open the pump box when received and inspect for evidence of rough handling or damage to the pump and 

verify the product ordered. If damage is found, notify the freight carrier and contact the vendor purchased 

from immediately. For order discrepancies, contact the vendor purchased from immediately.  

If using smaller than 1.5” pipe, excessive fittings such as elbows, sweeps or reducers, using an excessively 

long pipe run, additional strainers or any other water flow restriction device, can increase the time to reach full flow. 

Refer to the Pump Operation information on page 3.

9.    When determining pump placement, it is important to consider the distance and height from the 

       

  

water source. To reach full flow without an inline swing type check valve, the pump should be positioned  

 

                                   

at or below the water source level unless a priming pot is installed. Positioning is also important to 

     

            

maintain the pumps ability to maintain prime and minimize cavitation. 

       

Do not use spring loaded check valves!

 

   

4

WARNING

Содержание Cascade Series

Страница 1: ..._______ DATE PURCHASED ___________________ 5976 SE Alexander St Ste F Hillsboro OR 97123 P 503 356 5888 F 503 356 1660 E sales performancepropumps com WWW PERFORMANCEPROPUMPS COM For questions regarding installation operation or maintenance call 503 356 5888 Retain this information for future reference ...

Страница 2: ...and entire suction line must be filled with water for proper operation prior to starting the pump Running dry will void the warranty and can result in permanent damage to the pump unit 5 To prevent incorrect motor rotation install a ball or swing type check valve Do not use spring check valves 6 Maintain a minimum flow rate of at least two gallons per minute to avoid damage to the pump unit 7 Visu...

Страница 3: ...essure The best installation location for a check valve is underwater when possible as this can provide an air tight fit even without PVC adhesive Some swing check valves have true union connection fittings that offer easier access for cleaning when needed The pump housing intake pipe and strainer pot if present are then filled with water until the intake pipe is full Secure fittings tightly and t...

Страница 4: ...MPF 215 or standard 1 5 NPT PVC fittings available at your local hardware store and should be connected to PVC or flex pipe plumbing All plumbing lines should be well supported and properly aligned This will prevent undue stress to the housing and fittings Use a good primer and PVC cement to glue pipe connections 7 Installations in which the water level is elevated above the pump it is highly reco...

Страница 5: ...ns in which plumbing allows for trapped air in the system If this happens priming will be difficult In this case loosen the discharge fitting slightly to allow trapped air to bleed off Once primed tighten the discharge fitting 9 On flooded suction systems where the water source is higher than the pump the pump will fill with water once the supply valve is opened However on both flooded and non flo...

Страница 6: ...otate clockwise Incorrect rotation could destroy the pump and void the warranty If sequence of the incoming electrical supply lines is not known briefly connect the power for a second or two to determine the rotation while looking at the fan through the motor end plate on the back end opposite drive end of the motor If you are unable to see the fan you will need to remove the drip cover solid plat...

Страница 7: ... Refer to page 3 for further details If the pump runs dry the volute main pump housing may be hot allow the pump a minimum of one hour to cool before opening the pipe or pump The volute housing or strainer pot if attached should be cool to the touch before opening Danger of burn if opened when hot Seals and Bearings Pump seals and bearings experience normal wear and degrade over time It is recomme...

Страница 8: ...nscrew the impeller by turning it counter clockwise as viewed from the 7 Loosen and remove the four 4 1 hex bolts that hold the bracket to the motor face Slide the bracket away from the motor 6 To remove the shaft seal place the bracket face down on a flat surface and press out the mechanical seal from the back side Never pry it out from the front Carefully remove the ceramic seal from the back of...

Страница 9: ... WARNING 6 Make sure the volute o ring is clean and install the large o ring in the volute groove Tip Installing the volute o ring with the volute intake port side down will ease installation of the bracket o ring 7 Assemble the motor sub assembly to the volute using the seven 7 2 3 4 hex bolts Do not tighten until all seven 7 hex bolts are in place and hand tightened then tighten all seven 7 bolt...

Страница 10: ...s If strainer pot is installed the lid may be loosened to facilitate better drainage Tip Store drain plugs and union or fitting o rings in a resealable bag and tape the bag to the pump to prevent loss 3 Once drained loosen the intake and discharge port connections 4 The pump can now be removed Be sure the pump is fully drained and if strainer pot is installed remove the lid before being stored The...

Страница 11: ...or shaft by hand to test If shaft does not freely spin replace bearings Low flow Water flow has slowed or is Clean filter basket of debris if strainer pot installed intermittent Check for impeller clog See disassembly instructions or call for details Check for leaks in volute housing lid and union connections only if strainer pot installed Check for obstructions in plumbing and clear if found Moto...

Страница 12: ...na MPS 513 PTFE Coated S S with SIC Buna MPS 517 Bracket Bracket Rear Housing in Noryl PNB 10 Bracket Rear Housing in Polypropylene PPB 10 Drain Plug Noryl Drain Plug with O Ring 1 PND 20 Polypropylene Drain Plug with O Ring 1 PPD 10 Hardware Washers and Nuts Set of Stainless Steel Hardware includes 2 3 4 Bolts 1 Bolts MPH 20 Volute O Ring Volute O Ring PBO 10 Includes 2 Drain plug o rings 1 Brack...

Страница 13: ...Performance Data 13 PERFORM ANCE ...

Страница 14: ... how long an implied warranty lasts so in such States and except as is otherwise provided by applicable law of said States no action on a warranty implied at law shall be commenced more than one year following the date of purchase No action shall be brought for breach of any express warranty subsequent to the expiration of the express written warranty 7 Incidental and consequential damages specifi...

Страница 15: ...reduced service life of your pump Protect your pump motor from the elements today Excellent weather protection Noise abatement Easy to assemble Sturdy construction Customizable precut knockout sections Fits Artesian Artesian 2 ArtesianPro and Cascade series MPC 10 14 15 15 Part ...

Отзывы: