![Performance Motion Devices Juno MC71112 Скачать руководство пользователя страница 74](http://html.mh-extra.com/html/performance-motion-devices/juno-mc71112/juno-mc71112_user-manual_1529620074.webp)
Motion Monitoring & Control
74
Juno Step Motor Control IC User Guide
12
The default value of the signal sense mask is “not inverted” except for the
Index
signal, which has a default value of
“inverted.” The bits of the signal sense mask register are defined in the following table:
12.2 FaultOut Signal
Juno’s
FaultOut
signal is used to indicate an occurrence of a fault condition. This signal is always active high and its
sense cannot be changed. Any bit condition of the Event Status register may be used to trigger activation of this signal
via a user-programmable mask value.
The bit conditions specified in this mask are logically ANDed with the Event Status register. Any resultant non-zero
value will cause the
FaultOut
signal to go active. See
Section 12.1.1, “Event Status Register”
for information on the
Event Status register.
Example
Programming the fault out mask with a value of 1,040 (0x410) configures the
FaultOut
signal to be driven high upon a
motion error (bit #4) or a drive exception error (bit #10).
12.3 Event Action Processing
Juno ICs provide a programmable mechanism for automatically reacting to various safety or performance-related
events. This mechanism is called event action processing.
Each monitored event condition may have an associated event action defined for it. The following table lists each of
the event conditions that Juno monitors along with the default event actions that will occur if no user specified event
actions are provided:
Bit
Name
Interpretation
0
A encoder
Set 1 to invert quadrature A input signal. Clear 0 for no inversion.
1
B encoder
Set 1 to invert quadrature B input signal. Clear 0 for no inversion.
2
Index encoder
Set 1 to invert, clear 0 for no inversion. This means that for active low
interpretation of index signal, set to 0; and for active high interpretation, set to 1.
3-6
Reserved
7
AtRest
Set 1 to invert AtRest signal. Clear 0 for no inversion.
8-10
Reserved
11
Pulse
Set 1 to define active transition as low-to-high. Clear 0 to define active transition as
high-to-low.
12
Motor Direction
Set 1 to invert Motor Direction. Clear 0 for no inversion.
13–14
Reserved
15
Direction
Set to 1 to invert Direction signal. Clear 0 for no inversion.
Condition Name
Default Action
Description
Motion error
Disable Motor Output
Occurs when a motion error condition is detected
Current foldback
Disable Motor Output
Occurs when the amplifier current output goes into a
foldback condition.
Encoder Position Capture
No Action
Occurs when the quadrature encoder Index signal has
triggered a position capture
Overtemperature
Disable Motor Output
Occurs when an overtemperature condition is detected
Disabled
Disable Motor Output
Occurs when the Enable signal goes inactive. The pro-
grammed event action must be Disable Motor Output or
Brake
Содержание Juno MC71112
Страница 12: ...The Juno IC Family 12 Juno Step Motor Control IC User Guide 1 This page intentionally left blank ...
Страница 18: ...Functional Characteristics 18 Juno Step Motor Control IC User Guide 2 This page intentionally left blank ...
Страница 22: ...Electrical Characteristics 22 Juno Step Motor Control IC User Guide 3 This page intentionally left blank ...
Страница 26: ...Timing Diagrams 26 Juno Step Motor Control IC User Guide 4 This page intentionally left blank ...
Страница 46: ...Operational Overview 46 Juno Step Motor Control IC User Guide 7 This page intentionally left blank ...
Страница 54: ...Microstep Waveform Generation 54 Juno Step Motor Control IC User Guide 8 This page intentionally left blank ...
Страница 70: ...Internal Profile Generation 70 Juno Step Motor Control IC User Guide 11 This page intentionally left blank ...
Страница 78: ...Motion Monitoring Control 78 Juno Step Motor Control IC User Guide 12 This page intentionally left blank ...
Страница 86: ...Drive DC Bus Safety 86 Juno Step Motor Control IC User Guide 13 This page intentionally left blank ...
Страница 100: ...Application Notes MC74113 MC75113 100 Juno Step Motor Control IC User Guide 15 Figure 15 3 Drive Safety and Monitoring ...
Страница 103: ...Application Notes MC74113 MC75113 Juno Step Motor Control IC User Guide 103 15 Figure 15 4 Leg Current Sensing ...
Страница 114: ...Application Notes MC74113 MC75113 114 MC58113 Electrical Specifications 15 This page intentionally left blank ...