7
3111435 | ED. 01 | 01 - 2021
- Do not reversely connect the 12V power supply or the GND wire to the 0-10V terminal.
- The product is compatible with push dimming mode.
- Due to the diameter differences of the cables used by customers, there may be gaps between nuts and studs during assembly. It’s a normal phenomenon. To ensure the waterproof function, please make sure the torque is
within 2.8-3.7N/m.
- Use this product according to the specifications, please. Otherwise there may be malfunction.
- Use luminaires that have not been certified or are not compatible with the drivers may cause fire, explosion or other hazards.
- Man-made damage is not covered by warranty.
ATTENTION
- The default setting is 10V , the maximum output.
- Connect the DALI signal to DA1 and DA2 terminals.
- The DALI protocol includes 16 groups and 64 IP addresses.
- The minimum dimming depth of the DALI dimming is 10%.
- The DALI dimming function and push dimming function cannot be used at the same time, otherwise the DALI dimmer will be damaged.
Instruction of DALI Dimming
ouput
voltage
(V)
ouput
voltage
(V)
DALI logarithmic dimming curve
DALI linear dimming curve
DALI instruction
DALI instruction
- The wire outlets are compatible with two-core or three-core cables of 22# to 16# rubber or sheathed wires. (Expose 4mm to 6mm wire core. Peel 14mm to 16mm sheath. Use cables with the diameter of 5mm to 8mm.)
Structure & Dimension (unit: mm)
Ø 30
111 (Max)
Ø 30
Label