USB hardware delays and time-outs: 

USB transfer time-out: The time-out value for Control, Bulk, and Interrupt transfers. The options are 1 
sec, 5 sec, 10 sec, 20 sec. 
Device reset time-out: USB mass storage device Start Unit command time-out. The options are 10 sec, 
20 sec, 30 sec, 40 sec. 
Device power-up delay: Maximum time the device will take before it properly reports itself to the Host 
Controller. ‘Auto’ uses default value: for a Hub port the delay is taken from Hub descriptor. The options 
are Auto, manual. 

 
3.4.10 IT8786 Super IO Configuration 
System Super IO Chip Parameters. 

 

 
Serial Port 1 Configuration 
Set Parameters of Serial Port 0 (COMA). 

Serial Port:

 

Enable or Disable Serial Port (COM). 

Device Settings: IO=3F8h, IRQ=4 
Change Settings: Select an optimal setting for Super IO device. 

 
Serial Port 2 Configuration 
Set Parameters of Serial Port 1 (COMB). 

Serial Port:

 

Enable or Disable Serial Port (COM). 

Device Settings: IO=2F8h, IRQ=3 
Change Settings: Select an optimal setting for Super IO device. 
 

 

 

Содержание SR100

Страница 1: ...Version 1 0 Revision Date JAN 20 2015 www perfectron com SR200 MIL STD Rugged Computer User s Manual MIL STD Rugged Computer User s Manual ...

Страница 2: ...l power company If the power supply is broken do not try to fix it by yourself Contact a qualified service technician or your local distributor Operation safety Before installing the motherboard and adding devices on it carefully read all the manuals that came with the package Before using the product make sure all cables are correctly connected and the power cables are not damaged If you detect a...

Страница 3: ...r User s Manual If any of the above items is damaged or missing please contact your local distributor Ordering information Model Number Description SR200 ET Intel QM87 MIL STD Fanless Rugged System with Intel Core i7 4700EQ Haswell Processor NVIDIA GT730M GPU 4 Independent DP 9V to 36V DC in Wide Temp 20 to 60 C SR200 UT Intel QM87 MIL STD Fanless Rugged System with Intel Core i7 4700EQ Haswell Pr...

Страница 4: ...PANEL CONNECTOR PIN DEFINITIONS 9 Status Indicators 9 LED1 LAN1 LED STATUS 9 LED2 LAN2 LED STATUS 9 LED3 POWER HDD LED 9 USB3 0 CN19 USB 2 9 DP1 2 3 4 DISPLAY PORT 10 PWRIN1 DC Adapter Power Input 10 2 2 REAR PANEL CONNECTOR PIN DEFINITIONS 10 LAN1 Intel I217LM 10 LAN2 Intel I210IT 10 COM1 RS232 422 485 with 5V 12V selectable 10 USB3 0 CN18 USB 2 11 MIC 1 Audio Jacks Connector 11 LOUT 1 Audio Jack...

Страница 5: ...ial Port 5 Configuration 33 Serial Port 6 Configuration 33 3 4 11 IT8786 HW Monitor 34 3 4 12 Serial Port Console Redirection 34 Console Redirection Setting 35 3 4 13 Network Stack 35 3 4 14 Intel I210 Gigabit Network Connection 36 3 5 CHIPSET 37 3 5 1 PCH IO configuration 37 PCI Express Configuration 38 PCI Express Root Port1 38 PCI Express Root Port2 39 PCI Express Root Port3 40 PCI Port 4 is as...

Страница 6: ...l Block Rear I O Ethernet 2 x RJ45 COM 1 x RS232 422 485 with 5V 12V selectable USB 2 x USB 3 0 Audio 1 x MIC 1 x Line out Display Display Interface DP x 4 Resolution Up to 3840 x 2160 GPU NVIDIA GT730M embedded on PCIe 104 form factor Mechanical Environment Power Requirements 9V to 36V DC in AT ATX mode supports with power delay on off Dimension W x H x D 308 x 149 x 76 mm 121 26 x 58 66 x 29 92 ...

Страница 7: ...ation Method 516 6 Procedure I Mechanical Shock Method 501 5 Procedure I Storage High Temperature Method 501 5 Procedure II Operation High Temperature Method 502 5 Procedure I Storage Low Temperature Method 502 5 Procedure II Operation Low Temperature Method 503 5 Procedure I Temperature shock EMC CE and FCC compliance Green Product RoHS WEEE compliance Specifications are subject to change without...

Страница 8: ...Front Panel Components 1 2 x USB 3 0 2 1 x RS232 422 485 with 5V 12V selectable 3 LAN port 2 x RJ45 4 Audio jack 1 x MIC 1 x Line out 1 3 Back Panel Components 1 2 x DisplayPort 2 Power Input 9 36V DC in 3 Power Button 4 System LAN LED 5 2 x USB 3 0 Type A 6 2 x DisplayPort ...

Страница 9: ...SR200 MIL STD Rugged Computer User s Manual V1 0 www perfectron com 1 4 Mechanical Dimensions ...

Страница 10: ...h RED 1000M 100M NA GREEN LINK UNLINK ACTIVITY LED2 LAN2 LED STATUS LED2 Light Dark Flash RED 1000M 100M NA GREEN Link Un link Activity LED3 POWER HDD LED LED2 Light Dark Flash RED NA HDD un access HDD access GREEN Power On Power Off NA USB3 0 CN19 USB 2 LOWER USB UPPER USB PIN DEFINITION PIN DEFINITION 1 USB_VCC2 10 USB_VCC3 2 USBD0 11 USBD1 3 USBD0 12 USBD1 4 GND 13 GND 5 USB_SSRX3N_C 14 USB_SSR...

Страница 11: ...FINITION 1 VIN 2 VIN 3 GND 4 GND 2 2 Rear Panel Connector Pin Definitions LAN1 Intel i217LM LAN2 Intel I210IT LAN1 LAN2 PIN DEFINITION PIN DEFINITION A1 LAN1_MDI0_DP B1 LAN2_MDIP0 A2 LAN1_MDI0_DN B2 LAN2_MDIN0 A3 LAN1_MDI1_DP B3 LAN2_MDIP1 A4 LAN1_MDI1_DN B4 LAN2_MDIN1 A7 LAN1_MDI2_DP B7 LAN2_MDIP2 A8 LAN1_MDI2_DN B8 LAN2_MDIN2 A9 LAN1_MDI3_DP B9 LAN2_MDIP3 A10 LAN1_MDI3_DN B10 LAN2_MDIN3 COM1 RS2...

Страница 12: ...5 MIC_L 4 GND 3 NC 2 MIC1_R 1 GND LOUT 1 Audio Jacks Connector PIN DEFINITION 5 FRONT_L 4 GND 3 NC 2 FRONT_R 1 GND 2 3 Internal Connector MCARD1 Mini PCIE Card Slot COLAY M SATA PIN DEFINITION PIN DEFINITION 1 WAKE 2 3 3VAUX 3 COEX1 4 GND 5 COEX2 6 1 5V 7 CLKREQ 8 UIM_PWR 9 GND 10 UIM_DATA 11 REFCLK 12 UIM_CLK 13 REFCLK 14 UIM_RESET 15 GND 16 UIM_VPP 17 Reserved 18 GND 19 Reserved 20 W_Disable 21 ...

Страница 13: ...SR200 MIL STD Rugged Computer User s Manual V1 0 www perfectron com 41 3 3VAUX 42 LED_WWAN 43 GND 44 LED_WLAN 45 Reserved 46 LED_WPAN 47 Reserved 48 1 5V 49 Reserved 50 GND 51 Reserved 52 3 3VAUX ...

Страница 14: ...ost of the BIOS setup utility hot keys can be used at any time during the setup navigation process Some of the hot keys are F1 F10 Enter ESC and Arrow keys Some of the navigation keys may differ from one screen to another Left Right The Left and Right Arrow keys moves the cursor to select a menu Up Down The Up and Down Arrow keys moves the cursor to select a setup screen or sub screen Plus Minus T...

Страница 15: ...Setup is entered unless an error has occurred You could setup these items on the Main menu System Language Choose the system default language System Date Set the date Use Tab to switch between date elements System Time Set the time Use Tab to switch between time elements Access Level Displays the access level of the current user in the BIOS ...

Страница 16: ...STD Rugged Computer User s Manual V1 0 www perfectron com 3 4 Advanced Menu This section allows you to configure and improve your system and allows you to set up some system features according to your preference ...

Страница 17: ... Relaxed Ordering Enables or Disables PCI Express Device Relaxed Ordering Extended Tag If ENABLED allows Device to use 8 bit Tag field as a requester No Snoop Enabled or Disables PCI Express Device No Snoop option Maximum Payload Set Maximum Payload of PCI Express Device or allow System BIOS to select the value Maximum Read Request Set Maximum Read Request Size of PCI Express Device or allow Syste...

Страница 18: ...o save power software will disable unpopulated PCI Express Links If this option save to Disable Link Restore PCIE Registers On non PCI Express aware OS s some device may not be correctly reinitial after S3 Enableling this restore PCI Express device configurations on S3 resume Warning Enabling this may cause issues with other hardware after S3 resume 3 4 2 ACPI Settings System ACPI Parameters Enabl...

Страница 19: ...om ACPI Sleep State Select ACPI sleep state the system will enter when the suspend button is pressed Lock Legacy Resources Enable or disable lock of legacy resource S3 Video Repost Enable or disable S3 Video Repost 3 4 3 CPU configuration CPU Configuration Parameters ...

Страница 20: ...SR200 MIL STD Rugged Computer User s Manual V1 0 www perfectron com ...

Страница 21: ...enable in each processor package Overclocking lock FLEX_RATIO 194 MSR Limit CPUID Maximum Disable for Windows XP Execute Disable Bit XD can prevent certain classes of malicious buffer overflow attecks when combined with a supporting OS Intel Virtualization Technology When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Hardware Prefetcher Enable the...

Страница 22: ...d to unlock the register CPU Power Limit3 CPU Power Limit3 value CPU Power Limit3 Time Time window which the power limit3 is maintained CPU Power Limit3 Duty Cycle Specify the duty cycle in percentage that the CPU is required to maintain over the configured Power Limit3 time windows DDR Power Limit1 DDR Power limit1 value DDR Power Limit1 Time Time window which the DDR Power Limit1 is maintained D...

Страница 23: ...ackage C state demotion enable package C state demotion C1 state auto undemotion undemotion from demoted C1 C3 state auto undemotion undemotion from demoted C1 Package C state undemotion enable package C state undemotion C state Pre wake Enable or disable C state Pre Wake feature CFG lock Configure MSR 0xE2 15 CFG lock bit Package C State limit C0 C1 C2 C3 C6 C7 C7s AUTO LakeTiny Feature Enable Di...

Страница 24: ...f Spec ACPI Thermal Management uses EC reported temperature values and DTS SMM is used to handle Out of spec Debug interface Enable Disable CPU debug feature Debug interface lock Lock CPU debug interface setting IOUT OFFSET Sign 0 positive offset 1 negative offset IOUT OFFSET VR IOUT OFFSET configuration 0 625 IOUT SLOPE VR IOUT SLOPE configuration range 0 1023 3 4 4 SATA Configuration This sectio...

Страница 25: ...e Selection Determines how SATA controller s operate The options are IDE AHCI RAID SATA Test Selection Enable or disable Test Mode Aggressive LPM Support Enable PCH to aggressively enter link power state SATA Controller Speed Indicates the maximum speed the SATA controllers can support The options are default Gen1 Gen2 Gen3 ...

Страница 26: ...bled then only IRRT volumes can span internal and eSATA drives If disabled then any RAID volume can span internal and eSATA drives Smart Response Technology Enabled or disable Smart Response Technology OROM UI Delay If enabled indicates the delay of the OROM UI Splash Screen in a normal status The options are 2 seconds 4 seconds 6 seconds 8 seconds Serial ATA Port 0 Port 0 Enable or disable SATA p...

Страница 27: ...e Drive or Hard Disk Drive Spin Up Device On an edge detec from 0 to 1 the PCH starts a COMRESET initialization sequence to the device Serial ATA Port 4 Port 4 Enable or disable SATA port Hot Plug Designates this port as Hot Pluggable External SATA External SATA support SATA device type Identify the SATA port is connected to Solid State Drive or Hard Disk Drive Spin Up Device On an edge detec from...

Страница 28: ...l V1 0 www perfectron com 3 4 5 Intel Rapid Start Technology Enable or disable Intel Rapid Start Technology 3 4 6 PCH FW Configuration Configure Management Engine Technology Parameters MDES BIOS Status Code Enable Disable MDES BIOS Status Code ...

Страница 29: ...Image Re Flash Enable Disable Me FW Image Re Flash function 3 4 7 Intel Anti Theft Technology Configuration Disabling Intel AT allow user to login to platform This is strictly for testing only This does not disable Intel AT services in ME Intel Anti Theft Technology Enable Disable Intel AT in BIOS for testing On Enter Intel AT Suspend Mode Only Disabled ...

Страница 30: ...abled this requires additional firmware in the SPI device BIOS Hotkey Pressed OEMFlag Bit 1 Enable Disable BIOS hotkey press MEBx Selection Screen OEMFlag Bit 2 Enable Disable MEBx selection screen Hide Un Configure ME Confirmation OEMFlag Bit 6 Hide Un Configure ME without password Configuration prompt MEBx Debug Message Output OEMFlag Bit 14 Enable MEBx debug message output Un Configure ME OEMFl...

Страница 31: ... Temporary Disabled ASF Enable Disable Alert Specification Format Activate Remote Assistance Process Trigger CIRA boot USB Configure Enable Disable USB Configure function PET Progress User can Enable Disable PET Events progress to receive PET events or not WatchDog Enable Disable WatchDog Timer ...

Страница 32: ...eep USB devices available only for EFI applications USB3 0 Support Enable Disable USB3 0 XHCI Controller support XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver EHCI Hand off This is a workaround for OSes without EHCI hand off support The EHCI ownership change should be claimed by EHCI driver USB Mass Storage Driv...

Страница 33: ... reports itself to the Host Controller Auto uses default value for a Hub port the delay is taken from Hub descriptor The options are Auto manual 3 4 10 IT8786 Super IO Configuration System Super IO Chip Parameters Serial Port 1 Configuration Set Parameters of Serial Port 0 COMA Serial Port Enable or Disable Serial Port COM Device Settings IO 3F8h IRQ 4 Change Settings Select an optimal setting for...

Страница 34: ...ial Port Enable or Disable Serial Port COM Device Settings IO 2E8h IRQ 7 Change Settings Select an optimal setting for Super IO device Serial Port 5 Configuration Set Parameters of Serial Port 4 COME Serial Port Enable or Disable Serial Port COM Device Settings IO 2F0h IRQ 7 Change Settings Select an optimal setting for Super IO device Serial Port 6 Configuration Set Parameters of Serial Port 5 CO...

Страница 35: ...MIL STD Rugged Computer User s Manual V1 0 www perfectron com 3 4 11 IT8786 HW Monitor Monitor hardware status 3 4 12 Serial Port Console Redirection Console Redirection Console Redirection Enable or Disable ...

Страница 36: ...sole Redirection Settings page for more Help with Terminal Type Emulation The options are VT100 VT100 VT UTF8 ANSI Bits per second selects serial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds The options are 9600 19200 57600 115200 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receivi...

Страница 37: ...bit Ethernet device parameters PORT CONFIGURATION MENU NIC Configuration Configure Boot Protocol wake on LAN Link Speed and VLAN Blink LEDs Identify the physical network port by blinking the associated LED PORT CONFIGURATION INFORMATION Link Status Link Status Virtual MAC Address Programmatically assignable MAC address for port ...

Страница 38: ...anual V1 0 www perfectron com 3 5 Chipset This section gives you functions to configure the system based on the specific features of the chipset The chipset manages bus speeds and access to system memory resources 3 5 1 PCH IO configuration ...

Страница 39: ...ss Device Correctable Error Reporting CTO Enable or disable PCI Express Completion Timer TO SEFE Enable or disable Root PCI Express System Error on Fatal Error SENFE Enable or disable Root PCI Express System Error on Non Fatal Error SECE Enable or disable Root PCI Express System Error on Correctable Error PME SCI Enable or disable PCI Express PME SCI Hot Plug Enable or disable PCI Express Hot Plug...

Страница 40: ...Fatal Error SENFE Enable or disable Root PCI Express System Error on Non Fatal Error SECE Enable or disable Root PCI Express System Error on Correctable Error PME SCI Enable or disable PCI Express PME SCI Hot Plug Enable or disable PCI Express Hot Plug PCIe Speed Select PCI Express port speed Detect Non Compliance Device Detect Non Compliance PCI Express Device If enable it will take more time at ...

Страница 41: ...Fatal Error SENFE Enable or disable Root PCI Express System Error on Non Fatal Error SECE Enable or disable Root PCI Express System Error on Correctable Error PME SCI Enable or disable PCI Express PME SCI Hot Plug Enable or disable PCI Express Hot Plug PCIe Speed Select PCI Express port speed Detect Non Compliance Device Detect Non Compliance PCI Express Device If enable it will take more time at ...

Страница 42: ...ystem Error on Fatal Error SENFE Enable or disable Root PCI Express System Error on Non Fatal Error SECE Enable or disable Root PCI Express System Error on Correctable Error PME SCI Enable or disable PCI Express PME SCI Hot Plug Enable or disable PCI Express Hot Plug PCIe Speed Select PCI Express port speed Detect Non Compliance Device Detect Non Compliance PCI Express Device If enable it will tak...

Страница 43: ...Fatal Error SENFE Enable or disable Root PCI Express System Error on Non Fatal Error SECE Enable or disable Root PCI Express System Error on Correctable Error PME SCI Enable or disable PCI Express PME SCI Hot Plug Enable or disable PCI Express Hot Plug PCIe Speed Select PCI Express port speed Detect Non Compliance Device Detect Non Compliance PCI Express Device If enable it will take more time at ...

Страница 44: ...Fatal Error SENFE Enable or disable Root PCI Express System Error on Non Fatal Error SECE Enable or disable Root PCI Express System Error on Correctable Error PME SCI Enable or disable PCI Express PME SCI Hot Plug Enable or disable PCI Express Hot Plug PCIe Speed Select PCI Express port speed Detect Non Compliance Device Detect Non Compliance PCI Express Device If enable it will take more time at ...

Страница 45: ...or bridges behind this Root Bridge Reseved Memory Reserved Memory Range for this Root Bridge Prefetchable Memory Prefetchable Memory Range for this Root Bridge Reserved I O Reserved I O 4K 8K 12K 16K 48K Range for this Root Bridge PCIE LTR PCIE Latency Reporting Enable Disable PCIE LTR Lock PCIE LTR Configuration Lock Snoop Latency Ocerride Snoop Latency Ocerride for PCH PCIE Non Snoop Latency Oce...

Страница 46: ...Wake From DeepSx Wake from DeepSx by the assertion of GP27 pin PCIE Wake From DeepSx Wake from DeepSx by the assertion of PCIE Serial IRQ Mode Configure Serial IRQ Mode SLP_S4 Assertion Width Select a minimum assertion width of the SLP_S4 signal Port 80h Redirection Control where the Port 80h cycles are sent 3 5 2 System AGENT SA VT d Check to enable VT d function on MCH ...

Страница 47: ...hich will be activated during POST This has no effect if external graphics present Secondary boot display selection will appear based on your selection VGA modes will be supported only on primary display LCD Panel Type Select LCD panel used by Internal Graphics Device by selecting the appropriate setup item SDVO LFP Panel Type Select SDVO panel used by Internal Graphics Device by selecting the app...

Страница 48: ...s indefinite waiting Bootup NumLock State Select the keyboard NumLock state Quiet Boot Enables or disables Quiet Boot option Fast Boot Enables or disables boot with initialization of a minimal set of devices required to launch active boot option Has no effect for BBS boot options Boot option priorities Boot Option 1 Sets the system boot order Hard Drive BBS Priorities Set the order of the legacy d...

Страница 49: ...code is executed above 1MB Option ROM Messages Set display mode for option ROM INT19 Trap Response BIOS reaction on INT19 trapping by option ROM IMMEDIATE execute the trap right away POSTPONES execute the trap during legacy boot CSM Parameters OpROM execution boot options filter etc 3 7 Security Use the Security Menu to establish system passwords Administrator Password Set Administartor Password U...

Страница 50: ...s and Exit Exit system setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Options Save Changes Save Changes done so far to any of the setup options Discard Changes Discard Changes done so far to any of the setup options Restore Defaults Restore Load Default values for all the...

Страница 51: ...nual V1 0 www perfectron com Restore user Defaults Restore the User Defaults to all the setup options Launch EFI Shell from filesystem device Attempts to launch EFI Shell application Shellx64 efi from one of the available filesystem devices ...