SR200 MIL-STD Rugged Computer User’s Manual V1.0
www.perfectron.com
Software Feature Mask Configuration
RADI OROM/RST driver will refer to the SWFW configuration to enable or disable the storage features.
RAID0: Enable or disable RAID0 feature.
RAID1: Enable or disable RAID1 feature.
RAID10: Enable or disable RAID10 feature.
RAID5: Enable or disable RAID5 feature.
Intel Rapid Recovery Technology: Enable or disable Intel Rapid Recovery Technology.
OROM UI and Banner: If enabled, then the OROM UI is shown. Otherwise, no OROM banner
or information will be displayed if all disks and RAID volumes are Normal.
HDD unlock: If enabled, indicates that the HDD password unlock in the OS is enabled.
LED Locate: If enabled, indicates that the LED/SGPIO hardware is attached and ping yo locate features is
enabled on the OS.
IRRT Only on eSATA: If enabled, then only IRRT volumes can span internal and eSATA drives. If disabled,
then any RAID volume can span internal and eSATA drives.
Smart Response Technology: Enabled or disable Smart Response Technology.
OROM UI Delay: If enabled, indicates the delay of the OROM UI Splash Screen in a normal status. The
options are 2 seconds, 4 seconds, 6 seconds, 8 seconds.
Serial ATA Port 0
Port 0: Enable or disable SATA port
Hot Plug: Designates this port as Hot Pluggable.
External SATA: External SATA support.
SATA device type: Identify the SATA port is connected to Solid State Drive or Hard Disk Drive.
Spin Up Device: On an edge detec from 0 to 1, the PCH starts a COMRESET initialization sequence to the
device.
Serial ATA Port 1
Port 1: Enable or disable SATA port
Hot Plug: Designates this port as Hot Pluggable.
External SATA: External SATA support.
SATA device type: Identify the SATA port is connected to Solid State Drive or Hard Disk Drive.
Spin Up Device: On an edge detec from 0 to 1, the PCH starts a COMRESET initialization sequence to the
device.