9

Remove the 

upper drain plug

Continuous 

drain hose

Press the power cord buckle

into the rear cover.

FIG. 23

FIG. 24

FIG. 25

FIG. 26

Remove the  

upper drain plug

Continuous  

drain hose

Threaded Adapter 

(for garden hose 

draining option)

 WATER DRAINAGE

During dehumidifying mode, remove the upper drain plug from 

the back of the unit and attach 3/4” vinyl tube included with 

the unit (5/8” outer diameter). If a longer hose is needed, a vinyl 

tube (3/4” inner diameter 5/8” outer diameter) can be purchased 

at a local hardware store or a standard garden hose (not 

included) may be attached to the threaded adapter and used for 

continuous draining (for models with threaded adapters only). (A 

hose length of no greater than 6 ft is recommended.) Place the 

open end of the hose directly over the drain area in your floor. 

See Fig. 23 & 24.

NOTE: 

Make sure the hose is secure so there are no leaks. 

Direct the hose toward a floor drain, making sure that there 

are no kinks that will stop the water flow. Place the end of the 

hose into a drain and make sure the end of the hose is directed 

downward to let the water flow smoothly. (See Fig. 23.) Never 

allow the hose to be directed upward at any point. (Fig. 25.) 
When the water level of the bottom tray reaches a 

predetermined level, the unit beeps 8 times and the digital 

display area shows “P1”. At this time the air conditioning/

dehumidification process will immediately stop. However, the 

fan motor will continue to operate. (This is normal.) Carefully 

move the unit to a drain location, remove the bottom drain plug 

and drain the water (Fig. 26). You can carefully tilt the unit back 

slightly to assist with drainage. Restart the machine until the 

“P1” symbol disappears. If the P1 symbol will not clear after 

following the above instructions and waiting a few minutes after 

restarting the machine, call Consumer Services. 

NOTE: Be sure to reinstall the bottom drain plug before using  

the unit.

Содержание PORTQ12000

Страница 1: ...PORTABLE AIR CONDITIONER FOR MODEL PORTQ12000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Страница 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Страница 3: ...listed in the accessories chart of this Instruction Manual ENERGY SAVING TIPS Use the unit in the recommended room size Locate the unit where furniture cannot obstruct the air flow Keep blinds curtai...

Страница 4: ...replacement work should be performed by authorized personnel only Installation and repair work must be performed in accordance with the national wiring standards by authorized personnel only DO NOT op...

Страница 5: ...be pulled into water or any other liquid If the unit does ever fall into water unplug it immediately DO NOT install the unit in a location that may be exposed to combustible gas or other flammable li...

Страница 6: ...c Security Bracket and 2 Screws 1 set Drain Hose 1 pc Power Cord Buckle 1 pc ON OFF TEMP S HO R T C U T T IME R O N T IME R O F F MO DE FAN S L E E P S W ING L E D Remote Control and Batteries 1 set N...

Страница 7: ...e following 1 Plug in the air conditioner 2 The power supply cord will have TWO buttons on the plug head Press the TEST button The RESET button will click as it pops out 3 Press the RESET button again...

Страница 8: ...for you to improvise or modify some aspects of the installation procedures for certain types of windows Please refer to Fig 6 and Fig 7 for minimum and maximum window openings Window slider kit length...

Страница 9: ...t of the exhaust hose 20 inch clearance in order to ensure the exhaust system works properly Fig 12 Once the Exhaust Hose assembly and Adjustable Window Slider are prepared choose from one of the foll...

Страница 10: ...he glass and the window frame to prevent air and insects from getting into the room STEP 4 Fig 16 If desired install the security bracket with 2 screws as shown STEP 5 Fig 17 Insert the window slider...

Страница 11: ...the glass and the window frame to prevent air and insects from getting into the room STEP 4 Fig 21 If desired install the security bracket with 2 screws as shown STEP 5 Fig 22 Insert the window slider...

Страница 12: ...so there are no leaks Direct the hose toward a floor drain making sure that there are no kinks that will stop the water flow Place the end of the hose into a drain and make sure the end of the hose is...

Страница 13: ...the hose directly over the drain area in your basement floor or over a shallow pan if no floor drain is available See Fig 23 24 Remove the plug from the bottom drain outlet the water in the bottom tra...

Страница 14: ...y settings in a range of 35 RH Relative Humidity to 85 RH in 5 increments only for models with humidity sensor NOTE The control is capable of displaying the temperature in degrees Fahrenheit or degree...

Страница 15: ...es until the FOLLOW ME button is pressed again If the unit does not receive the Follow Me signal during any 7 minute interval the unit will beep to indicate use of the Follow Me feature has ended The...

Страница 16: ...uto timer settings ad the humidity settings for models with humidity sensor only when on DRY and FAN modes it shows the room temperature It also shows the following Error and Protection Codes ERROR AN...

Страница 17: ...filter Refer to Care and Cleaning section To defrost set to FAN only mode Thermostat is set too cold for night time cooling To defrost the coil set to FAN only mode Then set temperature to a higher se...

Страница 18: ......

Страница 19: ......

Страница 20: ...Perfect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_PORTQ...

Отзывы: