background image

CARE AND MAINTENANCE

     1)  Be sure to unplug the unit before cleaning or servicing.

     2)  Do not use gasoline, thinner or other chemicals to clean 

          the unit.

     3)  Do not wash the unit directly under a tap or using a hose.

          It may cause electrical danger.

     4)  If the power cord is damaged, it should be repaired by 

          an authorized repairman.

IMPORTANT:

1.   Air filter

-     Clean the air filter at least once every two weeks to prevent 

      inferior fan operation because of dust. 

-     Removal 

      This unit has two filters. Take the upper filter out along the

      arrow direction as shown in Fig. 23. Remove the lower filter 

      by loosening the screw and taking out the filter as shown in 

      Fig. 23.      

-     Cleaning 

      Wash the air filter by immersing it gently in warm water

      (about 104

O

F/40

O

C) with a mild detergent. Rinse the filter 

      and dry it in a cool, dry place. 

-     Mounting 

      Install the upper and lower air filters after cleaning as shown

      in Fig. 24. Be sure to use the screw for the lower filter.

2.   Unit enclosure

-     Use a lint-free cloth soaked with mild detergent to clean 

      the unit enclosure. Finish by using a dry, clean cloth.

3.   Unit idle for a long time

-     Remove the rubber plug at the back of the unit and attach

      a hose to drain outlet. Place the open end of the hose 

      directly over the drain area in your basement floor or over a

      shallow pan (if no floor drain is available.) (See Fig. 21 & 22.)

-     Remove the plug from the bottom drain outlet; all of the water 

      in the bottom tray will drain out (See Fig. 22.) 

-     Keep the appliance running on FAN mode for half a day in 

      a warm room to dry the appliance inside and prevent mold

      from forming.

-     Stop the appliance and unplug it. Wrap the cord and bundle 

      it with the band. Remove the batteries from the remote control.  

-     Clean the air filter and reinstall it.

-     Disconnect the exhaust hose. Keep it safe and cover the 

      window (wall) hole with the adaptor cap or remove slider kit

      from the window (wall) completely.

NOTE: 

The upper grille and upper air filter are connected and 

 

can be separated. The same is true for the lower grille 

 

and lower air filter.

13

Fig. 23

Upper filter

(take out)

 

Remove the 

screw ,then

take the lower

filter out. 

Fig. 24

Upper filter

(install)

 

Install the lower

filter by using

the screw.

 

Содержание NP12000

Страница 1: ......

Страница 2: ...ey do not play with the air conditioner Disabled persons may require assistance with set up If the power cord is to be replaced replacement work should be performed by authorized personnel only Instal...

Страница 3: ...hemicals to clean or come into contact with the unit Do not use the unit in the presence of flammable substances or vapor such as alcohol insecticides petrol etc Do not allow children to operate the u...

Страница 4: ...ION OF PARTS Exhaust hose 1 Set Flat mouth adaptor Window slider kit with bolt Vent joint Foam Seal 1 Piece Wall exhaust adaptor A 1 Set Round mouth adaptor B Expansion Plugs Wooden Screws Not include...

Страница 5: ...ade swings automatically Caster Carrying Handle both sides 1 2 3 4 Rear Bottom Tray Drain Outlet Upper Air Filter behind the grille Air Outlet Power Cord Outlet Air Intake Drain Outlet Air Intake Lowe...

Страница 6: ...gle The louver swing up to an angle of 6O for each press Keep pressing the button more than 2 seconds can initiate the auto swing feature TIMER button Used to initiate the AUTO ON start time and AUTO...

Страница 7: ...e page 11 FAN operation Press the MODE button until the HEAT indicator light comes on Press the ADJUST buttons or to select your desired room temperature The temperature can be set within a range of 6...

Страница 8: ...rection adjustment Fig 4 SLEEP operation If the unit breaks off unexpectedly due to the power being cut it will restart with the previous function setting automatically when the power is restored Auto...

Страница 9: ...04 ft 123 cm Fig 6 Fig 7 Window Slider Kit Minimum 2 22 ft 67 5 cm Maximum 4 04 ft 123 cm 7 7 8 Fig 7a Extension piece NOTE If the window opening is less than 2 22 ft cut the extension piece see Fig 7...

Страница 10: ...INSTALLATION INSTRUCTIONS CONTINUED Window sill Window sill Fig 8 See Fig 8 See Fig 10 See Fig 11 sill See Fig 9 Fig 9 26 5 48 Fig 10 Fig 11 9...

Страница 11: ...INSTALLATION INSTRUCTIONS CONTINUED 26 5 48 See Fig 12 See Fig 14 See Fig 15 sill See Fig 13 height of height of Fig 12 Fig 13 Fig 14 Fig 15 10...

Страница 12: ...n screws These parts are not included They are sold separately Contact customer service 1 Prepare a hole in the wall Install the wall exhaust adaptor A onto the wall outside by using 4 expansion plugs...

Страница 13: ...nit beeps 8 times and the digital display area shows P1 At this time the air conditioning dehumidification process will immediately stop However the fan motor will continue to operate this is normal C...

Страница 14: ...with mild detergent to clean the unit enclosure Finish by using a dry clean cloth 3 Unit idle for a long time Remove the rubber plug at the back of the unit and attach a hose to drain outlet Place the...

Страница 15: ...r filter may be dirty Clean filter Refer to Care and Maintenance section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then...

Страница 16: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in PRC 877 365 6274 www per...

Отзывы: