background image

4

 BEFORE YOU BEGIN

Read these instructions completely and carefully. 

IMPORTANT

- Save these instructions.

IMPORTANT

- Observe all governing codes  

and ordinances.

Note to Installer

- Be sure to leave these instructions with 

the Consumer.

Note to Consumer

- Keep these instructions for future 

reference.

Skill level

- Installation of this appliance requires basic 

mechanical skills.

Completion time

- Approximately 1 hour.

We recommend that two people install this product.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not 

covered under the Warranty.
You MUST use all supplied parts and use proper 

installation procedures as described in these 

instructions when installing this air conditioner.

 WINDOW REQUIREMENTS

Your air conditioner is designed to install in standard 

double hung windows with opening widths of 23 to 36 

inches (584 mm to 914 mm).

Inner sill

Offset

Window

Sill
Exterior

Interior wall

23–36 in.

14 in.

Sash

CAUTION

DO NOT

, under any circumstances, cut or remove the 

third (ground) prong from the power cord.

DO NOT

 change the plug on the power cord of the  

air conditioner.
Aluminum house wiring may present special problems- 

consult a qualified electrician.
When handling unit, be careful to avoid cuts from sharp 

metal edges and aluminum fins on front and rear coils.

TOOLS YOU WILL NEED

●  Phillips Screwdriver

●  Level

TOOLS YOU MAY NEED

●  Flathead Screwdriver

●  Pencil

●  Ruler or Tape Measure

●  Scissors or Knife

HARDWARE

Included - packed with the unit.

(Included - Packed with the Unit)

3/4ʺ (or 1/2ʺ)

Screws

3/4

ʺ

 (or 1/2

ʺ

)

Screws (7 pcs)

Lock Frame

(2 pcs)

Sash Lock

(1 pc)

Window 

Sash Seal 

Foam (1 pc)

Weather Stripping

10

ʺ

x

3

/

4

ʺ

x

1

/

12

ʺ

(5 pcs)

7 pcs

Lock Frame

3/4

ʺ

 (or 1/2

ʺ

)

Screws (7 pcs)

Lock Frame

(2 pcs)

Sash Lock

(1 pc)

Window 

Sash Seal 

Foam (1 pc)

Weather Stripping

10

ʺ

x

3

/

4

ʺ

x

1

/

12

ʺ

(5 pcs)

2 pcs

Sash Lock

1 pc

Window Sash  

Seal Foam

3/4

ʺ

 (or 1/2

ʺ

)

Screws (7 pcs)

Lock Frame

(2 pcs)

Sash Lock

(1 pc)

Window 

Sash Seal 

Foam (1 pc)

Weather Stripping

10

ʺ

x

3

/

4

ʺ

x

1

/

12

ʺ

(5 pcs)

1 pc

Weather Stripping

10ʺ x 3/4ʺ x 1/12ʺ

3/4

ʺ

 (or 1/2

ʺ

)

Screws (7 pcs)

Lock Frame

(2 pcs)

Sash Lock

(1 pc)

Window 

Sash Seal 

Foam (1 pc)

Weather Stripping

10

ʺ

x

3

/

4

ʺ

x

1

/

12

ʺ

(5 pcs)

5 pcs

3/8ʺ Screws

3/8" Screws

(4 pcs)

Top Rail

(1 pc)

Insulation 

Panels (2 pcs)

4 pcs

Top Rail

3/8" Screws

(4 pcs)

Top Rail

(1 pc)

Insulation 

Panels (2 pcs)

1 pc

Insulation Panels

3/8" Screws

(4 pcs)

Top Rail

(1 pc)

Insulation 

Panels (2 pcs)

2 pcs

Accordion Panels 

(one left, one right)

1 set

INSTALLATION INSTRUCTIONS

Содержание 5PAC6000

Страница 1: ...WINDOW AIR CONDITIONER FOR MODEL 5PAC6000 5PAC8000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Страница 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Страница 3: ...ller for installation of this unit The air conditioner is not intended for use by young children without adult supervision Young children should be supervised to ensure that they do not play with the...

Страница 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Страница 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire Do not place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Страница 6: ...sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this un...

Страница 7: ...e power cord of the air conditioner Aluminum house wiring may present special problems consult a qualified electrician When handling unit be careful to avoid cuts from sharp metal edges and aluminum f...

Страница 8: ...pcs C Align the hole in the top rail with those in the top of the unit as shown in Fig B D Secure the top rail to the unit with the 3 8 screws as shown in Fig C NOTE For safety reasons all four 4 scr...

Страница 9: ...r is tilted back approximately 3 4 to 1 Fig 5 above tilted about 3 to 4 downward to the outside If after proper installation condensation does not drain from the overflow drain hole during normal use...

Страница 10: ...ter the unit is installed in the window measure the inner width of one of the accordion panels as shown in Fig 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 STEP 6 2 Mark a line on one of t...

Страница 11: ...caulked or painted shut Accumulated rain water or condensation must be allowed to drain out FIG 15 Sash Storm window frame or other obstruction 1 min 38 mm Board thickness as required for proper pitch...

Страница 12: ...ng the unit This unit can be controlled by the unit control or with the remote control FOLLOW ME Indicator Energy Saver Mode Sets Mode Sleep Mode Turns Unit On or Off Set Fan Speed Adjusts Temp or Tim...

Страница 13: ...goes from AUTO COOL DRY and FAN The indicator light will be illuminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver function under COOL DRY and AUTO...

Страница 14: ...ally when the power resumes AIR DIRECTIONAL LOUVERS Use the 4 way directional louvers to direct the air flow up or down and left or right throughout the room as needed Pivot horizontal louvers until t...

Страница 15: ...hot water over 104 F 40 C to clean the air filter Never attempt to operate the unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The c...

Страница 16: ...oil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the room Re...

Страница 17: ......

Страница 18: ......

Страница 19: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Страница 20: ...01 Dansher Road Countryside IL 60525 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_5PAC600...

Отзывы: