background image

8

7

 REMOVING THE COLLECTED WATER: 2 OPTIONS

OPTION 1: USE THE BUCKET

A dehumidifier operating in one room will have little or no effect in 

drying an adjacent enclosed area, such as a closet, or other room 

unless there is adequate circulation in the area.

•  If the bucket is full when the unit is OFF, the unit will beep 8 times, 

the Full indicator light will flash and the display will show P2.

•  If the bucket is full when the unit is ON, the compressor will turn 

off followed by the fan 30 seconds later. The unit will then beep 8 

times, the full indicator light will flash and the display will show P2.

•  Unplug the unit before removing the bucket. Slowly pull out the 

bucket. Grip the left and right sides securely, and carefully pull 

out straight so water does not spill. Use the handle to carry the 

bucket. 

DO NOT

 put the tank on the floor because the bottom of the 

bucket is uneven. The bucket will fall and cause the water to spill.

•  Throw away the water and replace the bucket. The bucket must be 

in place securely for the dehumidifier to operate. (

DO NOT

 drink the water.)

•  The unit will re-start 3 minutes after the bucket is placed in its correct position.

NOTES: 

•  When you remove the bucket, do not touch any parts inside of the unit. Doing so may damage the unit. 

•  Be sure to push the bucket gently all the way into the unit. Improper installation or failing to push it in securely may 

cause the unit not to operate.

•  When you remove the bucket, be sure to wipe away any excess moisture found inside the unit.

OPTION 2: CONTINUOUS DRAINING

Water can be automatically emptied into a floor drain by attaching 

a water hose, garden hose, or dehumidifier drain hose to the 

dehumidifier. (Garden hose must have a female threaded end. Hose 

not included.)

•  If not already assembled, put together the “Drain Tube 

Subassembly” by securely connecting the drain tube (included) to 

the garden hose adapter (included). (See Fig. 9.) Drain tube and 

adapter can be found inside the bucket.

•  Remove the rubber plug from the drain outlet on the back of the 

unit and set aside or in the bucket for safe keeping. Remove 

bucket to access connector. Insert the drain hose through the 

unit’s drain outlet (from the back of the unit going forward) and 

securely press into the connector on the inside of the unit. (Fig. 10 

& 11)

•  Tighten the garden hose adapter to the unit by using the two 

4x5/8” screws provided, which can be found inside a pouch in the 

packaging with this user manual.

•  Install the female threaded end of the water hose, garden hose, 

or dehumidifier drain hose into the garden hose adapter (Fig. 12); 

Then lead the water hose to the floor drain or a suitable  

drainage facility.

•  A hose length of no more than 6 ft. is recommended as the hose 

must allow the water to continuously travel downward into the drain.

•  Make sure the hose is secure to avoid leakage.

•  Direct the hose down toward the drain, making sure that there are 

no kinks that will stop the water flow.

•  Place the end of the hose into the drain and make sure the end of 

the hose is level or down to let the water flow smoothly.

 NEVER LET 

DRAIN HOSE GO UPWARD AGAINST GRAVITY.

•  Place the bucket back in the unit in the proper position. The unit 

will not run if the bucket is not in the proper place.

•  Select the desired humidity setting and fan speed on the unit for 

continuous draining to start.

NOTES:

•  CONTINUOUS mode and continuous draining are different. You 

do not need to be on CONTINUOUS mode to do continuous draining. See pg. 3 for details about CONTINUOUS mode.

•  To eliminate the use of the drain tube adapter assembly and still drain to the floor you may use tubing (5/8” O.D. 1/2” 

I.D.) in the length required (up to 6 ft.) to go directly from the unit to floor drain.

 

OPTION 1: USE THE BUCKET

FIG. 7

FIG. 8

1. Pull the bucket  

    out slightly.

3. Dispose of water; replace bucket into proper position.

2. Hold both sides of the bucket      

    with even strength and pull it  

    out from the unit.

OPTION 2: CONTINUOUS DRAINING

FIG. 9: Drain Tube Subassembly

FIG. 10

FIG. 11

FIG. 12

Drain tube

Rubber plug

Rubber plug

Water hose

Female threaded end of water 

hose connected to the  

garden hose adapter

Connector

Drain tube

Drain tube 

subassembly

Garden Hose 

Adapter

NOTE: When the continuous drain feature is not being used, 

remove the garden hose adapter and drain tube from the 

outlet and insert drain plug. Failure to re-insert the drain 

plug will result in unit malfunction and possible error codes.

CARE AND MAINTENANCE

 CARE AND CLEANING OF THE DEHUMIDIFIER

TURN THE DEHUMIDIFIER OFF AND REMOVE THE PLUG FROM THE WALL 

OUTLET BEFORE CLEANING.

1.  CLEAN THE GRILLE AND CASE

•  Use a damp cloth with water and a mild detergent. Do not use 

bleach or abrasives.

•  Do not splash water directly onto the main unit. Doing so may 

cause electrical shock, cause the insulation to deteriorate, or 

cause the unit to rust.

•  The air intake and outlet grilles get soiled easily; use a vacuum 

attachment or brush to clean.

2.  CLEAN THE BUCKET

Every few weeks, clean the bucket to prevent growth of mold, mildew 

and bacteria. 
•  Remove the bucket and clean it in an area away from the 

dehumidifier to avoid splashing water onto/in the unit.

•  Partially fill the bucket with clean water and add a small amount of 

mild detergent. Swish it around in the bucket,empty and rinse.

NOTE: DO NOT

 use a dishwasher to clean the bucket. After cleaning the 

bucket, it must be securely in place for the dehumidifier to operate.

3.  CLEAN THE AIR FILTER

•  Remove and clean the filter when the filter light illuminates. For 

more frequent use, clean the filter more often (i.e. every 2 weeks).

•  Remove the filter from the top of the unit (See Fig. 13.)
•  Wash the filter with clean water, then dry thoroughly before re-

inserting the filter.

CAUTION: DO NOT

 operate the dehumidifier without a filter because dirt 

and lint will clog the unit and reduce performance.

3.  PROLONGED PERIODS OF NON-USE

•  After turning off the unit, wait one day before emptying the bucket.
•  Clean the main unit, water bucket and air filter and let  

dry completely.

•  Wrap the cord and bundle it with the band on the unit.  

(See Fig. 14).

•  Cover the unit with a plastic bag.
•  Store the unit upright in a dry, well-ventilated place.

FIG. 13: Removing the Filter

FIG. 14: Cord Storage

Содержание 4PAD30

Страница 1: ...2 POUR LES MODÈLES SUIVANTS 4PAD30 4PAD45 4PAD50 4PAD70 Before using your dehumidifier please read this manual and keep it for future reference along with your receipt Avant d utiliser votre déshumidificateur lisez ce manuel et gardez le pour y réferer en temps futur avec votre reçu en tant que preuve d achat ...

Страница 2: ...right position for a minimum of 24 hours before running it 2 When first using the dehumidifier operate the unit on CONTINUOUS mode for 24 hours First 24 hours on Continuous Mode Cont 3 After the first 24 hours should you wish to set a desired humidity you will need to take the unit off of Continuous You will not be able to select a desired humidity while the unit is set on Continuous mode NOTE You...

Страница 3: ...formed by authorized personnel only Installation and repair work must be performed in accordance with the national wiring standards by authorized personnel only This manual provides the information needed for proper use and maintenance of this dehumidifier Basic preventative care can help extend the life of this unit The Troubleshooting section in this manual contains a chart with possible solutio...

Страница 4: ...rille openings Be sure to warn children of dangers This may cause electric shock or failure of dehumidifier DO NOT place heavy objects on the power cord make sure the cord is not compressed There is danger of fire or electric shock DO NOT climb up on or sit on the unit You may be injured if you fall or if the unit falls over Always insert the filters securely Clean filter at least once every two w...

Страница 5: ...ch and foam are properly secured in bucket E1 UNIT MALFUNCTION Unplug the unit for at least 5 minutes and plug it back in If error repeats call Perfect Aire Consumer Services at 844 472 2473 EC HUMIDITY SENSOR ERROR Make sure the temperature of the working environment is between 41 F 5 C and 95 F 35 C If not please operate the unit under the correct stated temperature If on a concrete floor unplug...

Страница 6: ...e all around the unit for proper air circulation 16 or more from the top of the unit Place the unit in an area where the temperature will not fall below 41 F 5 C The coils can become covered with frost at temperatures below 41 F 5 C which may reduce performance and cause an error code Place the unit away from the clothes dryer heater or radiator Use the dehumidifier to prevent moisture damage anyw...

Страница 7: ... end of the hose is level or down to let the water flow smoothly NEVER LET DRAIN HOSE GO UPWARD AGAINST GRAVITY Place the bucket back in the unit in the proper position The unit will not run if the bucket is not in the proper place Select the desired humidity setting and fan speed on the unit for continuous draining to start NOTES CONTINUOUS mode and continuous draining are different You do not ne...

Страница 8: ...ARS ON THE DISPLAY These are error and protection codes See page 4 of this manual for more information NOTE A highly recommended troubleshoot for any issue in general consists of turning off unit and unplugging for 5 minutes It is also recommended to try another wall outlet For further assistance contact Consumer Services at 844 472 2473 BEFORE CALLING FOR SERVICE PLEASE REVIEW THE CHART BELOW ISS...

Страница 9: ...12 11 Conseils en matière de dépannage 21 I appareil 18 tilisation de U U U I appareil ...

Страница 10: ...lectrique Un choc ser un choc électrique ou un 13 arrêter l appareil à partir du panneau électrique principal La plaque signalétique est située sur le panneau arrière de l unité et contient les données électriques et techniques de l appareil Votre appareil doit être utilisé avec une prise à la terre murale Si la prise murale que vous avez l intention d utiliser n est pas mise à la terre correcteme...

Страница 11: ...t plein ou lorsque le bac a été retiré ou mal remis en place Arrêt automatique Le déshumidificateur s arrête automatiquement 30 secondes après lorsque le bac soit plein ou lorsque le bac a été retiré ou mal remis en place Lorsque l humidité préréglée est atteinte l appareil s arrête tout seul Pour certains modèles le moteur du ventilateur va continuer à fonctionner Dégivrage automatique Lorsque le...

Страница 12: ...sez le déshumidificateur dans un sous sol pour aider à prévenir les dommages de l humidité Le déshumidificateur doit être utilisé dans une zone fermée pour être le plus efficace Fermez toutes les portes fenêtres et autres ouvertures extérieures à la pièce Fig 4a Roulettes aux 4 coins sous la base Les roulettes peuvent se déplacer librement Ne forcez pas les roulettes à rouler sur du tapis et ne dé...

Страница 13: ...tallez l extrémité filetée femelle du tuyau d eau dans l adaptateur ou une installation de drainage approprié Placez l extrémité du tuyau dans le drain et assurez vous que l extrémité du tuyau est à niveau égal ou inférieur pour laisser retirez le tuyau de vidange de la prise à égalité devez la sécher avec une extrémité filetée femelle diam ext 26mm non inclus dans le bac Reserrez l adaptateur A e...

Страница 14: ...beau coup de bruit quand il fonctionne Du givre s accumule sur les serpentins Le filtre à air est bloqué L unité est inclinée alors qu elle devrait se trouver en position verticale Le plancher n est pas droit ıl y a de l eau sur le plancher ES AS EC et P2 apparaît à l écran Quoi vérifier C est normal Le déshumidificateur comporte une fonction de dégivrage automatique Le raccord du tuyau peut être ...

Страница 15: ...PERFECT AIRE LLC 5401 Dansher Road Countryside IL 60525 p 866 996 9255 f 630 323 2301 www perfectaire us support perfectaire us ...

Отзывы: