To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, 

including the following:

    If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first. If the window 

    is a triple-track type with a screen panel included, remove the screen completely before installation.

    Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual. 

    Save this manual for possible future use in removing or installing this unit.

    When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils. 

   

4

IMPORTANT SAFETY INSTRUCTIONS

Be sure the electrical service is adequate for the model you have  chosen. 
This information can be found on the serial plate, which is located on the 
side of the cabinet and behind the grille.
Be sure the air conditioner is properly grounded. To minimize shock and fire 

hazards, proper grounding is important. The power cord is equipped   with a 
three-prong grounding plug for protection against shock hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If 
the wall receptacle you intend to use is not adequately grounded or 

protected by a time delay fuse or circuit breaker, have a qualified electrician 

install the proper receptacle. 
Ensure the receptacle is accessible after the unit installation.
Do not run air conditioner without side protective cover in place. This could 
result in mechanical damage within the air conditioner. 

WARNING!  

DO NOT store or use gasoline or other flammable vapors or liquids in 

the vicinity of this or any other appliance.

Avoid fire hazard or electric shock. DO NOT use an extension cord or 

an adaptor plug. DO NOT remove any prong from the power cord.

WARNING! 

NOTE  

The power supply cord with

this air conditioner contains a current 

detection device designed to reduce 

the risk of fire.

Please refer to    

the section "Operation 

of Current Device" (below) for details.

In the event that the power supply cord 

is damaged, it MUST be replaced by 

an authorized repairman.

Operation of Current Device

1. Plug in the air conditioner.

2. The power supply cord will have TWO buttons on the plug head. Press the TEST

button. The RESET button will click as it pops out.

3. Press the RESET button; again you will notice a click as the button engages.

4. The power supply cord is now supplying electricity to the unit.

(On some products this is also indicated by a light on the plug head.)

           

                 

     

      

NOTES:

Do not use this device to turn the unit on or off.

Always make sure the RESET button is pushed in for correct operation.

The power supply must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset. 

If power supply cord is damaged, it cannot be repaired. Please call customer service to assist with replacement. 

 

TEST

RESET

Plug in &

press RESET

NOTE: Some plugs have

            buttons on the top.

DO NOT, under any

circumstances, cut,

remove, or bypass

grounding prong.

Power supply cord

with 3-prong grounding plug

and current detection device

The power supply cord contains a current device that senses damage to the power 
cord. To test your power supply cord do the following:   

NOTE:

This air conditioner is designed to be operated under conditions as follows:

If the unit is operated beyond the conditions specified above, it may cause a failure of the unit.

Cooling operation

Outdoor temp:  18-43°C/64-109°F (18-52°C/64-125°F for special tropical models)

Indoor temp: 

17-32°C/62-90°F

For Your Safety

Electrical Information

WARNING! 

Prevent Accidents

Do not use an extension cord or an adaptor plug.

Содержание 3PNC5000

Страница 1: ......

Страница 2: ...ontact an installer for installation of this unit if necessary The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they...

Страница 3: ...se explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may caus...

Страница 4: ...main power switch If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified serviced technic...

Страница 5: ...ctric shock DO NOT use an extension cord or an adaptor plug DO NOT remove any prong from the power cord WARNING NOTE The power supply cord with this air conditioner contains a current detection device...

Страница 6: ...g moved by the fan High Pitched Chatter High efficiency compressors may have a high pitched chatter during the cooling cycle Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passi...

Страница 7: ...L has a minimum cooling effect and airflow Fan Mode Rotate the Cooling knob to select your choice of fan speeds for air circulation NOTE When selecting a fan speed the compressor will NOT run Thermost...

Страница 8: ...conditioner BEFORE YOU BEGIN Do not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on the power cord of the air conditioner Aluminum ho...

Страница 9: ...ilization and drainage If you are not using the side panels for any reason this pitch to the rear must be maintained A Place unit on floor a bench or a table Hold the accordion panel in one hand and g...

Страница 10: ...is against the window sill Fig 5 Carefully close the window behind the top rail of the unit Fig 5 NOTE Check that air conditioner is tilted back approximately 5 8 to 3 4 tilted about 3O to 4O downwar...

Страница 11: ...or slots are not caulked or painted shut Accumulated rain water or condensation must be allowed to drain out Removing AC From Window Turn AC off and disconnect power cord Remove sash seal from betwee...

Страница 12: ...e stored during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton Always store unit in upright positio...

Страница 13: ...re and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher setting UNIT WILL NO...

Страница 14: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in PRC 877 365 6274 www per...

Отзывы: